3400 E 3RD ST 90063

Certificate Information: 3400 E 3RD ST 90063

Application / Permit
26016-70000-10458
Plan Check / Job No.
X26SL00522
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
Kitchen & bathroom remodel (no structural changes). Replace drywall (no new walls added) for single family dwellings. Install insulation in walls / floor for single family dwellings. (5) Window and (6) door change-out (same size & type) for residential buildings. Dual glazing, labeled andcertified by National Fenestration Rating Council (NFRC), is required for doors and windows replaced in all residential buildings, three stories or less, per Title 24, Part 6, Section 150.2(b) 1B. Fiber Cement siding over solid sheathing with an approved waterresistive barrier, per valid ICC Evaluation Report on exterior walls at 5 feet or more from property lines for residential buildings. (Applicant to provide a copy of the report to inspector). Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing (6) Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone (VHFHSZ). For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council (CRRC). Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0(b)2B. "Comply with department order. Permit to expire 30 days from issuance date."
Permit Issued
Issued on 4/21/2026
Issuing Office
South Los Angeles
Current Status
Issued on 4/21/2026

Permit Application Status History

Issued 4/21/2026 APPLICANT

Permit Application Clearance Information

No Data Available.

Contact Information

Contractor Owner-Builder       ,

Inspector Information

DANIEL DELACRUZ, (323) 526-9348 Office Hours: 7:00-8:00 AM MON-FRI
PEDRO SIERRA, (323) 526-9348 Office Hours: 7:00-8:00 AM MON-FRI
ROBERT MINASSIANS, (323) 526-9348 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

BUILDING-Rough-Frame 5/4/2026 Partial Approval DANIEL DELACRUZ
ELECTRICAL-Rough 5/4/2026 Not Ready for Inspection DANIEL DELACRUZ
HVAC-Rough 5/4/2026 Partial Approval DANIEL DELACRUZ
PLUMBING-Rough 5/4/2026 Partial Approval DANIEL DELACRUZ
BUILDING-Rough-Frame 5/28/2026 Approved DANIEL DELACRUZ
ELECTRICAL-Rough 5/28/2026 Approved DANIEL DELACRUZ
HVAC-Rough 5/28/2026 Partial Inspection DANIEL DELACRUZ
PLUMBING-Rough 5/28/2026 Approved DANIEL DELACRUZ