11640 W WEDDINGTON ST 91601
Certificate Information: 11640 W WEDDINGTON ST 91601
- Application / Permit
- 25047-20000-01725
- Plan Check / Job No.
- B25VN35889
- Group
- Building
- Type
- Swimming-Pool/Spa
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (20) Pool/Spa - Private
- Work Description
- EPLAN. NEW POOL PER LA CITY STANDARD PLAN #268.
- Permit Issued
- Issued on 1/22/2026
- Issuing Office
- Current Status
- Issued on 1/22/2026
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 12/11/2025 | APPLICANT |
| Assigned to Plan Check Engineer | 12/17/2025 | SARKIS HARABEDIAN |
| Corrections Issued | 12/18/2025 | SARKIS HARABEDIAN |
| Plan Check Approved | 1/14/2026 | SARKIS HARABEDIAN |
| No Progress | 1/14/2026 | SARKIS HARABEDIAN |
| Plan Check Approved | 1/14/2026 | SARKIS HARABEDIAN |
| Issued | 1/22/2026 | APPLICANT |
Permit Application Clearance Information
| Construction near power lines | Cleared | 1/7/2026 | GEVORK KARAPETYAN |
Contact Information
| Contractor | Athlon Pool Company Inc; Lic. No.: 970093-C53 | , |
| Engineer | Biedenbach,, Christopher James; Lic. No.: C74003 | 1201 N TUSTIN AVE ANAHEIM, CA 92807 |
Inspector Information
| JAVIER RAMOS JR, (818) 374-1163 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 1/30/2026 | Partial Approval | JAVIER RAMOS JR |
| Gas Piping or Gas Test | 3/5/2026 | Partial Approval | JAVIER RAMOS JR |
| Pool Piping | 3/5/2026 | Approved | JAVIER RAMOS JR |
| Pre-Gunite | 3/5/2026 | Approved | JAVIER RAMOS JR |
| Deck | 5/13/2026 | Not Ready for Inspection | JAVIER RAMOS JR |
| Deck | 5/18/2026 | Approved | JAVIER RAMOS JR |