9232 W BEVERLYWOOD ST 90034
Certificate Information: 9232 W BEVERLYWOOD ST 90034
- Application / Permit
- 25020-10000-00538
- Plan Check / Job No.
- B25LA08148
- Group
- Building
- Type
- Nonbldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (23) Retaining Wall
- Work Description
- ePlan. Proposed Retaining Wall at the front yard supported by grade beam and piles per engineering
- Permit Issued
- Issued on 11/24/2025
- Issuing Office
- Current Status
- Permit Finaled on 4/17/2026
Permit Application Status History
| Submitted | 3/4/2025 | APPLICANT |
| Assigned to Plan Check Engineer | 3/20/2025 | YASHAR EMAMI |
| Corrections Issued | 3/26/2025 | JAD BASMA |
| Quality Review Completed | 3/27/2025 | PRANITA SHAH |
| Applicant returned to address corrections | 10/10/2025 | JAD BASMA |
| Applicant returned to address corrections | 10/23/2025 | JAD BASMA |
| Applicant returned to address corrections | 10/30/2025 | JAD BASMA |
| Plan Check Approved | 10/31/2025 | JAD BASMA |
| Issued | 11/24/2025 | APPLICANT |
| Permit Finaled | 4/16/2026 | JOHNNY MIRANDA |
Permit Application Clearance Information
| Grading Pre-Inspection | Cleared | 10/31/2025 | JAD BASMA |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Gerges,, Atef; Lic. No.: NA94252 | , |
Inspector Information
| JOHNNY MIRANDA, (310) 914-3937 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Reinf. Concrete | 12/19/2025 | Conditional Approval | JOHNNY MIRANDA |
| Footing/Foundation/Slab | 12/19/2025 | Partial Approval | JOHNNY MIRANDA |
| Deputy Reinf. Concrete | 12/22/2025 | Conditional Approval | JOHNNY MIRANDA |
| Footing/Foundation/Slab | 12/22/2025 | Corrections Issued | JOHNNY MIRANDA |
| Excavation/Setback/Form/Re-Bar | 12/23/2025 | Partial Approval | JOHNNY MIRANDA |
| Masonry Wall/Backfill | 1/12/2026 | Partial Approval | JESUS RODRIGUEZ |
| Final | 3/17/2026 | Not Ready for Inspection | JOHNNY MIRANDA |
| Final | 4/16/2026 | Permit Finaled | JOHNNY MIRANDA |