5113 S 5TH AVE 90043
Certificate Information: 5113 S 5TH AVE 90043
- Application / Permit
- 25016-90000-18806
- Plan Check / Job No.
- --
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over new solid sheathing 16 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone (VHFHSZ). For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council (CRRC). Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0(b)2B. 14 window(s). Window and door change-out (same size & type) for residential buildings. Dual glazing, labeled and certified by National Fenestration Rating Council (NFRC), is required for doors and windows replaced in all residential buildings, three stories or less, per Title 24, Part 6, Section 150.2(b)1B. Replace existing siding with new stucco for single family dwellings and duplex only. Area = 1520 sqft. Add sill plate anchor bolts and plywood to cripple walls (if existing) per LA City Standard Plan #1; no foundation replacement (Earthquake hazard reduction per Chapter 92 of the Los Angeles Building Code). (Houses, residential buildings up to 3 stories and up to 4 units).
- Permit Issued
- Issued on 6/11/2025
- Issuing Office
- Current Status
- Permit Finaled on 2/26/2026
Permit Application Status History
| Issued | 6/11/2025 | INTERNET PERMIT |
| Permit Finaled | 2/26/2026 | STUART CHAPMAN |
Permit Application Clearance Information
| No Data Available. |
Contact Information
| Contractor | Hillside Structural And Foundations; Lic. No.: 1071420-B | 1312 CORDON DRIVE LOS ANGELES, CA 90063 |
Inspector Information
| LUIS CASTRO, (213) 202-3436 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Wood Frame | 7/14/2025 | Approved | RONNIE MEDINA |
| Interior/Exterior Lathing | 11/6/2025 | Partial Approval | ANTHONY RAMOS |
| Final | 2/26/2026 | Permit Finaled | STUART CHAPMAN |
| SGSOV-Seismic Gas S/O Valve | 2/26/2026 | SGSOV Approved | STUART CHAPMAN |
| Smoke Detectors | 2/26/2026 | Approved | STUART CHAPMAN |