3829 S WELLINGTON ROAD 90008

Certificate Information: 3829 S WELLINGTON ROAD 90008

Application / Permit
25016-90000-09060
Plan Check / Job No.
--
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over new solid sheathing 36 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone (VHFHSZ). For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council (CRRC). Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0(b)2B. 21 window(s). Window and door change-out (same size & type) for residential buildings. Dual glazing, labeled and certified by National Fenestration Rating Council (NFRC), is required for doors and windows replaced in all residential buildings, three stories or less, per Title 24, Part 6, Section 150.2(b)1B.
Permit Issued
Issued on 3/26/2025
Issuing Office
Current Status
Permit Finaled on 9/2/2025

Permit Application Status History

Issued 3/26/2025 INTERNET PERMIT
Permit Finaled 8/30/2025 RYAN SALAZAR

Permit Application Clearance Information

No Data Available.

Contact Information

Contractor Vista General Construction; Lic. No.: 937863-B 1441 HUNTINGTON DR STE 232      SOUTH PASADENA, CA 91030

Inspector Information

LUIS CASTRO, (213) 202-3436 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Floor/Roof Diaphrgm/Shear Wall 5/10/2025 Partial Approval ALEJANDRO DE ARTOLA
Final 8/28/2025 Corrections Issued LUIS CASTRO
Final 8/30/2025 Permit Finaled RYAN SALAZAR