3682 S BUCKINGHAM ROAD 90016
Certificate Information: 3682 S BUCKINGHAM ROAD 90016
- Application / Permit
- 25016-70000-03034
- Plan Check / Job No.
- X25SL00077
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- Re-roof with Class A or B material weighing less than 6 pounds per sq. ft. over New solid sheathing 22 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone (VHFHSZ). For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council (CRRC). Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0(b) 2B. 1 Kitchen 1 bathroom remodel for residential buildings (no structural changes 12 Window 7 doors change-out (same size & type) for residential buildings. Dual glazing, labeled and certified by National Fenestration Rating Council (NFRC), is required for doors and windows replaced in all residential buildings, three stories or less, per Section 150.2(b) 1B of Title 24 Including Mechanical, electrical and plumbing Replace drywall (no new walls added) for single family dwellings and duplexes only. Replacement of damaged framing members (less than 10% of replacement cost of building) for houses and duplexes (not including decks). "COMPLY WITH DEPARTMENT ORDER effective date 01/09/2025. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE". All permits shall be for the same time period limitation. If additional assistance is needed, please call Inspector LUIS CORRAL at (213)252-3957 of GENERAL ENFORCEMENT SOUTH
- Permit Issued
- Issued on 2/4/2025
- Issuing Office
- Current Status
- Permit Finaled on 12/26/2025
Permit Application Status History
| Issued | 2/4/2025 | APPLICANT |
| Permit Finaled | 12/26/2025 | LUIS CORRAL |
Permit Application Clearance Information
| No Data Available. |
Contact Information
| Contractor | Coast Men Construction Inc; Lic. No.: 1108397-B | , |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| ELECTRICAL-Rough | 5/31/2025 | Not Ready for Inspection | MORRIS JACKSON |
| Gas Test | 5/31/2025 | Not Ready for Inspection | MORRIS JACKSON |
| HVAC-Rough | 5/31/2025 | Not Ready for Inspection | MORRIS JACKSON |
| Interior/Exterior Lathing | 5/31/2025 | Not Ready for Inspection | MORRIS JACKSON |
| PLUMBING-Rough | 5/31/2025 | Not Ready for Inspection | MORRIS JACKSON |
| Wood Frame | 5/31/2025 | Not Ready for Inspection | MORRIS JACKSON |
| ELECTRICAL-Rough | 6/3/2025 | Not Ready for Inspection | LUIS CASTRO |
| Gas Test | 6/3/2025 | Not Ready for Inspection | LUIS CASTRO |
| HVAC-Rough | 6/3/2025 | Not Ready for Inspection | LUIS CASTRO |
| PLUMBING-Rough | 6/3/2025 | Not Ready for Inspection | LUIS CASTRO |
| Wood Frame | 6/3/2025 | Not Ready for Inspection | LUIS CASTRO |
| ELECTRICAL-Rough | 6/4/2025 | Approved | LUIS CORRAL |
| Gas Test | 6/4/2025 | Approved | LUIS CORRAL |
| PLUMBING-Rough | 6/4/2025 | Approved | LUIS CORRAL |
| BUILDING-Rough-Frame | 6/6/2025 | Approved | LUIS CORRAL |
| Insulation | 6/6/2025 | Approved | LUIS CORRAL |
| Interior/Exterior Lathing | 6/6/2025 | Approved | LUIS CORRAL |
| Drywall Nailing | 6/11/2025 | Approved | LUIS CORRAL |
| HVAC-Rough | 6/11/2025 | Corrections Issued | LUIS CORRAL |
| Final | 12/26/2025 | Permit Finaled | LUIS CORRAL |
| SGSOV-Seismic Gas S/O Valve | 12/26/2025 | SGSOV Approved | LUIS CORRAL |
| Smoke Detectors | 12/26/2025 | Approved | LUIS CORRAL |