1150 N ORLON AVE 90272
Certificate Information: 1150 N ORLON AVE 90272
- Application / Permit
- 25016-30000-06780
- Plan Check / Job No.
- X25WL01897
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- 2025 WILDFIRE DAMAGE A--(2) Window change-out (same size & type) for residential buildings. Dual glazing, labeled and certified by National Fenestration Rating Council (NFRC), is required for doors and windows replaced in all residential buildings, three stories or less, per Section 150.2(b) 1B of Title 24., B--Re-roof with Class A or B material weighing less than 6 pounds per sq. ft. over existing solid sheathing___40___Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone(VHFHSZ). For residential roof replacement>50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council (CRRC). Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141(b), C-- Replacement of damaged framing members (less than 10% of replacement cost of building), D--(Vinyl) (Wood)(Fiber Cement) (others: ) siding over solid sheathing with an approved water-resistive barrier per valid ICC Evaluation Report # __ESR-2290__ on exterior walls at 5 feet or more from property lines for residential buildings. (Applicant to provide a copy of the report to inspector). & E--Replace drywall (no new walls added) for single family dwellings and duplexes only.
- Permit Issued
- Issued on 3/11/2025
- Issuing Office
- West Los Angeles
- Current Status
- Issued on 3/11/2025
Permit Application Status History
| Issued | 3/11/2025 | APPLICANT |
Permit Application Clearance Information
| No Data Available. |
Contact Information
| Contractor | National Construction & Architecture Inc; Lic. No.: 793008-B | 15115 1/2 SUNSET BLVD #B PACIFIC PALISADES, CA 90272 |
Inspector Information
| DANIEL VERA, (213) 577-9924 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Floor/Roof Diaphrgm/Shear Wall | 4/17/2025 | Approved | STEPHANIE SWANSON |
| Wood Frame | 4/17/2025 | Approved | STEPHANIE SWANSON |
| Floor/Roof Diaphrgm/Shear Wall | 4/29/2025 | Approved | TEMISTOCLES CAAL |
| Interior/Exterior Lathing | 4/29/2025 | Approved | TEMISTOCLES CAAL |
| Insulation | 5/1/2025 | Approved | BOBBY KEY |
| Drywall Nailing | 5/8/2025 | Approved | BOBBY KEY |
| Interior/Exterior Lathing | 6/20/2025 | Approved | MEL KHACHATOURIAN |