16704 W VIA PACIFICA 90272
Certificate Information: 16704 W VIA PACIFICA 90272
- Application / Permit
- 25016-30000-03137
- Plan Check / Job No.
- X25WL00791
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- 2025 Wild Fire Project: 14 Windows and 3 door change-outs (same size & type) for residential buildings. Dual glazing, labeled and certified by National Fenestration Rating Council (NFRC), is required for doors and windows replaced in all residential buildings, three stories or less, per Section 150.2(b) 1B of Title 24 Replace existing siding with new stucco for single family dwellings and duplex only. Re-roof with Class A or B material weighing less than 6 pounds per sq. ft. over new solid sheathing _1500 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone (VHFHSZ). For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council (CRRC). Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141(b) 2B. Replace drywall (no new walls added) for single family dwellings and duplexes only. Install insulation in walls / floor for single family dwellings and duplex only. Fire damage repair for residential buildings only (maximum 10% of replacement cost of building). Replacement of damaged framing members (less than 10% of replacement cost of building) for houses and duplexes (not including decks). Repair of water, dry-rot or termite damaged stairs in residential buildings (less than 10% of replacement cost of stairs). Handrails for apartments, one and two family dwellings require plan check.
- Permit Issued
- Issued on 2/4/2025
- Issuing Office
- West Los Angeles
- Current Status
- Permit Finaled on 5/24/2025
Permit Application Status History
| Issued | 2/4/2025 | APPLICANT |
| Permit Finaled | 5/23/2025 | DANIEL VERA |
Permit Application Clearance Information
| No Data Available. |
Contact Information
| Contractor | Hallmark Construction Inc; Lic. No.: 843062-B | 8424 COLIMA ROAD WHITTIER, CA 90605 |
Inspector Information
| MICHAEL ALLEN, (310) 914-3886 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 3/18/2025 | Partial Inspection | TEMISTOCLES CAAL |
| Wood Frame | 4/7/2025 | Approved | STEPHANIE SWANSON |
| Drywall Nailing | 4/29/2025 | Approved | TEMISTOCLES CAAL |
| Insulation | 4/29/2025 | Approved | TEMISTOCLES CAAL |
| Interior/Exterior Lathing | 4/29/2025 | Approved | TEMISTOCLES CAAL |
| Final | 5/21/2025 | Corrections Issued | BOBBY KEY |
| Green Building Final | 5/21/2025 | Approved | BOBBY KEY |
| SGSOV-Seismic Gas S/O Valve | 5/21/2025 | SGSOV Not Ready | BOBBY KEY |
| Smoke Detectors | 5/21/2025 | Approved | BOBBY KEY |
| Final | 5/23/2025 | Permit Finaled | DANIEL VERA |
| SGSOV-Seismic Gas S/O Valve | 5/23/2025 | SGSOV Approved | DANIEL VERA |