300-302 N KENTER AVE 90049
Certificate Information: 300-302 N KENTER AVE 90049
- Application / Permit
- 25016-20000-31292
- Plan Check / Job No.
- B25VN30822
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- INTERIOR REMODEL TO SINGLE FAMILY DWELLING AND CONVERT ATTACHED GARAGE TO ACCESSORY DWELLING UNIT PER GC 66323(a)(1). COMPLY WITH DEPARTMENT ORDER effective date 11/17/2025. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE
- Permit Issued
- Issued on 12/4/2025
- Issuing Office
- West Los Angeles
- Current Status
- Issued on 12/4/2025
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 10/20/2025 | APPLICANT |
| Assigned to Plan Check Engineer | 10/27/2025 | JESSE ARELLANO |
| Corrections Issued | 10/28/2025 | JESSE ARELLANO |
| Building Plans Picked Up | 10/29/2025 | APPLICANT |
| Plan Check Approved | 11/20/2025 | ALEC MOUSAKHANIAN |
| Issued | 12/4/2025 | APPLICANT |
Permit Application Clearance Information
| Address approval | Cleared | 11/4/2025 | ROSE STEIN-WENDT |
| Sewer availability | Cleared | 11/4/2025 | ROSE STEIN-WENDT |
| Grading Pre-Inspection | Cleared | 11/14/2025 | LANNY MERRICK |
| Eng Process Fee Ord 176,300 | Cleared | 12/2/2025 | BIAINA HARITUNIAN |
Contact Information
| Contractor | Dolan Design & Build Llc; Lic. No.: 1135363-B | 1817 IOWA TRAIL TOPANGA, CA 90290 |
| Engineer | Wang,, Hongyu; Lic. No.: C72679 | 8887 W FALMINGO RD STE 101 LAS VEGAS, NV 89147 |
Inspector Information
| No Data Available. |
Pending Inspections
| Insulation | 6/10/2026 |
Inspection Request History
| Footing/Foundation/Slab | 1/22/2026 | Partial Approval | KEVIN SARGSYAN |
| Floor/Roof Diaphrgm/Shear Wall | 3/9/2026 | Corrections Issued | KEVIN SARGSYAN |
| Floor/Roof Diaphrgm/Shear Wall | 3/13/2026 | Partial Approval | KEVIN SARGSYAN |
| Wood Frame | 3/24/2026 | Partial Approval | KEVIN SARGSYAN |
| Insulation | 4/1/2026 | Partial Approval | KEVIN SARGSYAN |
| Floor/Roof Diaphrgm/Shear Wall | 4/9/2026 | Approved | KEVIN SARGSYAN |
| HVAC-Rough | 4/28/2026 | Corrections Issued | ANTHONY EGSON |
| ELECTRICAL-Rough | 4/29/2026 | Corrections Issued | KEVIN SARGSYAN |
| ELECTRICAL-Rough | 5/5/2026 | Not Ready for Inspection | KEVIN SARGSYAN |
| HVAC-Rough | 5/5/2026 | Approved | KEVIN SARGSYAN |
| PLUMBING-Rough | 5/5/2026 | Corrections Issued | KEVIN SARGSYAN |
| ELECTRICAL-Rough | 5/8/2026 | Approved | KEVIN SARGSYAN |
| PLUMBING-Rough | 5/8/2026 | Approved | KEVIN SARGSYAN |
| BUILDING-Rough-Frame | 5/11/2026 | Corrections Issued | KEVIN SARGSYAN |
| FLOOD-Proofing Certificate | 5/11/2026 | Approved | KEVIN SARGSYAN |
| Green Building Rough | 5/11/2026 | Approved | KEVIN SARGSYAN |
| Interior/Exterior Lathing | 5/11/2026 | Partial Approval | KEVIN SARGSYAN |
| BUILDING-Rough-Frame | 5/27/2026 | Approved | KEVIN SARGSYAN |