625 W COLLEGE ST 90012

Certificate Information: 625 W COLLEGE ST 90012

Application / Permit
25016-20000-23467
Plan Check / Job No.
X25VN22077
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Commercial
Primary Use
(16) Dental Clinic
Work Description
Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing (95) Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone (VHFHSZ). For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roofing Rating Council (CRRC). Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0(b)2B
Permit Issued
Issued on 7/31/2025
Issuing Office
Current Status
Permit Finaled on 8/19/2025

Permit Application Status History

Issued 7/31/2025 APPLICANT
Permit Finaled 8/19/2025 RONALD JIMENEZ

Permit Application Clearance Information

No Data Available.

Contact Information

Contractor Terrazas Roofing; Lic. No.: 852568-C39 8005 FRANKLIN ST      BUENA PARK, CA 90621

Inspector Information

SEAN POMISH, (213) 202-2643 Office Hours: 7:00-8:00 AM MON-FRI
RAFAEL CORTES, (213) 202-2643 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Floor/Roof Diaphrgm/Shear Wall 8/12/2025 Approved RONALD JIMENEZ
Final 8/19/2025 Permit Finaled RONALD JIMENEZ
SGSOV-Seismic Gas S/O Valve 8/19/2025 SGSOV Not Required RONALD JIMENEZ
Smoke Detectors 8/19/2025 Approved RONALD JIMENEZ