7175 W WOODROW WILSON DR 90068

Certificate Information: 7175 W WOODROW WILSON DR 90068

Application / Permit
25016-20000-20546
Plan Check / Job No.
X25VN18657
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
Replacement of damaged framing members (less than 10% of replacement cost of building) for houses and duplexes (not including decks). Replace drywall (no new walls added) for single family dwellings and duplexes only. Application of an LA City approved coating to an existing exterior balcony. Application of an approved coating to an existing roof. Window (38) and door (22) change-out (same size & type) for residential buildings. Dual glazing, labeled and certified by National Fenestration Rating Council (NFRC), is required for doors and windows replaced in all residential buildings, three stories or less, per Section 150.2(b) 1B of Title 24. Kitchen/bathroom (6) remodel for residential buildings (no structural changes). Re-stucco for residential buildings. Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing (6) Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone (VHFHSZ). For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roofing Rating Council (CRRC). Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0(b)2B. Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over new solid sheathing (4) Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone (VHFHSZ). For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roofing Rating Council (CRRC). Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0(b)2B. Metal siding over solid sheathing with an approved water-resistive barrier, per valid ICC Evaluation Report #ESR 2049 on exterior walls at 5 feet or more from property lines for residential buildings. (Applicant to provide a copy of the report to inspector).
Permit Issued
Issued on 6/30/2025
Issuing Office
Valley
Current Status
Issued on 6/30/2025

Permit Application Status History

Issued 6/30/2025 APPLICANT

Permit Application Clearance Information

No Data Available.

Contact Information

Contractor Owner-Builder       ,

Inspector Information

JOEL ORDAZ, (213) 252-3049 Office Hours: 7:00-8:00 AM MON-FRI
PTOLEMY HILL, (213) 252-3049 Office Hours: 7:00-8:00 AM MON-FRI
ARAM AVAKIAN, (213) 252-3049 Office Hours: 7:00-8:00 AM MON-FRI
EDMOND DECKERT, (213) 252-3049 Office Hours: 7:00-8:00 AM MON-FRI
TIMOTHY KEY, (213) 252-3049 Office Hours: 7:00-8:00 AM MON-FRI
ROBERT CHAVEZ, (213) 252-3049 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Floor/Roof Diaphrgm/Shear Wall 12/31/2025 Partial Approval ROY SPAULDING
Floor/Roof Diaphrgm/Shear Wall 2/6/2026 Approved JOEL ORDAZ
Floor/Roof Diaphrgm/Shear Wall 2/9/2026 Approved JOEL ORDAZ
Wood Frame 2/10/2026 Corrections Issued JOEL ORDAZ
Wood Frame 2/12/2026 Corrections Issued JOEL ORDAZ
Floor/Roof Diaphrgm/Shear Wall 3/20/2026 Not Ready for Inspection PTOLEMY HILL
Insulation 3/20/2026 Corrections Issued PTOLEMY HILL
Floor/Roof Diaphrgm/Shear Wall 3/25/2026 Approved JOEL ORDAZ
Insulation 3/25/2026 Approved JOEL ORDAZ
Wood Frame 3/25/2026 Approved JOEL ORDAZ
Drywall Nailing 4/6/2026 Approved JOEL ORDAZ
Interior/Exterior Lathing 4/8/2026 Approved PTOLEMY HILL
Interior/Exterior Lathing 4/20/2026 Approved JOEL ORDAZ