6553 N FARRALONE AVE 91303
Certificate Information: 6553 N FARRALONE AVE 91303
- Application / Permit
- 25016-20000-02820
- Plan Check / Job No.
- B25VN02487
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- REMOVE AND REPLACE PORTION OF EX ROOF FRAMING DUE TO FIRE/WATER DAMAGE & MISC COSMETIC REPAIRS AS EXISTED. REFRAME POR OF EX VAULTED CEILING/ROOF OVER LIVING RM AS EXISTED (NOT FIRE DAMAGED). REMODEL EX KITCHEN & BATHRMS. REMOVE & REPLACE EX 3 WINDOWS WITH DIFFERENT SIZE & TYPE PER PLAN. T/O AND REROOF W/ CLASS 'A' COOL ROOF COMPLIANT COMP SHINGLES OVER ENTIRE ROOF. REMOVE & REPLACE EXISTING SOLAR PANELS AS EXISTED.
- Permit Issued
- Issued on 12/19/2025
- Issuing Office
- Valley
- Current Status
- Issued on 12/19/2025
Permit Application Status History
| Submitted | 1/31/2025 | APPLICANT |
| Assigned to Plan Check Engineer | 2/7/2025 | HAYATO TSUCHIYA |
| Corrections Issued | 2/8/2025 | HAYATO TSUCHIYA |
| Building Plans Picked Up | 2/14/2025 | APPLICANT |
| Plan Check Approved | 4/2/2025 | HAYATO TSUCHIYA |
| Issued | 12/19/2025 | APPLICANT |
Permit Application Clearance Information
| No Data Available. |
Contact Information
| Contractor | La Family Builders Inc; Lic. No.: 1120579-B | 6355 TOPANGA CANYON BLVD STE 331 WOODLAND HILLS, CA 91367 |
| Engineer | Zarate,, Eduardo P; Lic. No.: C71359 | 1798 MARSALA WAY CAMARILLO, CA 93012 |
Inspector Information
| GEVORK IPCHYAN, (818) 774-4308 | Office Hours: 7:00-8:00 AM MON-FRI |
| TROY SANDERS, (818) 774-4308 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Drilled-In Anchors | 12/29/2025 | Conditional Approval | GEVORK IPCHYAN |
| Footing/Foundation/Slab | 12/29/2025 | Approved | GEVORK IPCHYAN |
| Floor/Roof Diaphrgm/Shear Wall | 2/13/2026 | Partial Approval | TROY SANDERS |
| ELECTRICAL-Rough | 3/11/2026 | Approved | TROY SANDERS |
| Floor/Roof Diaphrgm/Shear Wall | 3/11/2026 | Approved | TROY SANDERS |
| PLUMBING-Rough | 3/11/2026 | Approved | TROY SANDERS |
| BUILDING-Rough-Frame | 3/19/2026 | Not Ready for Inspection | JACK KARGODORIAN |
| HVAC-Final | 3/19/2026 | Not Ready for Inspection | JACK KARGODORIAN |
| Wood Frame | 3/19/2026 | Not Ready for Inspection | JACK KARGODORIAN |
| HVAC-Rough | 3/23/2026 | Approved | TROY SANDERS |
| Wood Frame | 3/23/2026 | Approved | TROY SANDERS |
| BUILDING-Rough-Frame | 5/12/2026 | Approved | TROY SANDERS |
| Interior/Exterior Lathing | 5/12/2026 | Approved | TROY SANDERS |
| Wood Frame | 5/12/2026 | Approved | TROY SANDERS |
| Insulation | 5/20/2026 | Approved | TROY SANDERS |
| Drywall Nailing | 5/27/2026 | Approved | TROY SANDERS |