7461 W BEVERLY BLVD 90036
Certificate Information: 7461 W BEVERLY BLVD 90036
- Application / Permit
- 25016-10000-34428
- Plan Check / Job No.
- B25LA49285
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Commercial
- Primary Use
- (15) Telecommunication Transmitter - wireless
- Work Description
- Eplan modify an existing WCF by: REMOVE 3 (E) panel Antennas REMOVE 3 (E) twin style 1A TMA REMOVE 6 (E) style 4 TMA REMOVE 1 (E) FRP Screen and abandoned antenna by others Install 2 (N) FW-65A-R3 Panel Antennas(1 at sector 'B' and 'C') INSTALL 1 (N) D2WC- 21 PANEL ANTENNAS INSTALL 6 (N) TMAT19G21BL26- 21 STYLE 3CY TMA INSTALL 2 (N) PIPE MOUNT (1 AT SECTORS 'B' AND 'C') REMOVE 3 (E) RRUS 11 B2 REMOVE 1 (E) PPC CABINET REMOVE 6 (E) DIPLEXERS (2 PER SECTOR) RETROFIT 1 (E) RBS 6102 CABINET TO POWER UP ANCHOR SOW INSTALL 3 (N) RRUS 4480 871 + 885 INSTALL 3 (N) RRUS 4460 B25+ B66 INSTALL 2 (N) RRUS 8863 B41 INSTALL 6 (N) CTX41727T-DS- 43 TWIN TRIPLEXER INSTALL 1 (N) 200A PPC CABINET INSTALL 2 (N) RP6651 INSTALL 1 (N) IXRE V2 ROUTER INSTALL 1 (N) DC POWER CABLE REEL 4AWG 300M 80M+ INSTALL 22 (N) MLA FIBER PAIR INSTALL 12 7 /8" COAX
- Permit Issued
- Issued on 1/22/2026
- Issuing Office
- Current Status
- Issued on 1/22/2026
Permit Application Status History
| Submitted | 12/9/2025 | APPLICANT |
| Assigned to Plan Check Engineer | 12/12/2025 | MINA HABILI |
| Corrections Issued | 12/12/2025 | MINA HABILI |
| Applicant returned to address corrections | 1/15/2026 | MINA HABILI |
| Plan Check Approved | 1/20/2026 | MINA HABILI |
| Issued | 1/22/2026 | APPLICANT |
Permit Application Clearance Information
| Plan Approval | Cleared | 12/23/2025 | POLONIA MAJAS |
| ZA Case | Cleared | 12/23/2025 | POLONIA MAJAS |
| ZA Case | Cleared | 12/23/2025 | POLONIA MAJAS |
Contact Information
| Contractor | Mastec Network Solutions Inc; Lic. No.: 984138-B | , |
| Engineer | Lee,, Chris; Lic. No.: NA61054 | , |
Inspector Information
| IAN BLINN, (213) 482-7361 | Office Hours: 7:00-8:00 AM MON-FRI |
| CHRISTOPHER BLACKWOOD, (213) 482-7361 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| No Data Available. |