12309 W 9TH HELENA DR 90049
Certificate Information: 12309 W 9TH HELENA DR 90049
- Application / Permit
- 25016-10000-33214
- Plan Check / Job No.
- B25LA47090
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- ePlan INTERIOR REMODEL TO (E) SFD. INSTALL NEW WINDOWS, DOORS, KITCHEN AND BATHROOM REPLACEMENTS. RECONFIGURE PRIMARY BATHROOM AND LAUNDRY. CREATE NEW POWDER ROOM.
- Permit Issued
- Issued on 12/8/2025
- Issuing Office
- Current Status
- Issued on 12/8/2025
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 11/7/2025 | APPLICANT |
| Assigned to Plan Check Engineer | 11/12/2025 | ISIS ARGUETA |
| Corrections Issued | 11/13/2025 | ISIS ARGUETA |
| Plan Check Approved | 12/4/2025 | ROSENDO MEDINA |
| Issued | 12/8/2025 | APPLICANT |
Permit Application Clearance Information
| Grading Pre-Inspection | Cleared | 11/20/2025 | LANNY MERRICK |
Contact Information
| Architect | Le, Clerc, Sarah Jane; Lic. No.: C39716 | 1134 CHELSEA AVE #B SANTA MONICA, CA 90403 |
| Contractor | 4 Eco Living; Lic. No.: 827016-B | , |
| Contractor | Thomas E Strebel; Lic. No.: 827016-B | , |
Inspector Information
| HERBERT GIRON, (310) 914-3891 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 1/20/2026 | Corrections Issued | HERBERT GIRON |
| Footing/Foundation/Slab | 2/5/2026 | Approved | HERBERT GIRON |
| Sewer | 2/5/2026 | Approved | HERBERT GIRON |
| ELECTRICAL-Rough | 4/23/2026 | Partial Approval | HERBERT GIRON |
| HVAC-Rough | 4/23/2026 | Corrections Issued | HERBERT GIRON |
| PLUMBING-Rough | 4/23/2026 | Partial Approval | HERBERT GIRON |
| HVAC-Rough | 5/1/2026 | Partial Approval | HERBERT GIRON |
| Insulation | 5/1/2026 | Partial Approval | HERBERT GIRON |
| Interior/Exterior Lathing | 5/1/2026 | Partial Approval | HERBERT GIRON |
| Shower Pan | 5/1/2026 | Approved | HERBERT GIRON |
| Drywall Nailing | 5/11/2026 | Partial Approval | ANTHONY EGSON |
| Gas Test | 5/15/2026 | Corrections Issued | HERBERT GIRON |
| PLUMBING-Rough | 5/15/2026 | Corrections Issued | HERBERT GIRON |
| Gas Test | 5/20/2026 | Approved | HERBERT GIRON |
| PLUMBING-Rough | 5/20/2026 | Partial Approval | HERBERT GIRON |
| HVAC-Rough | 5/21/2026 | Corrections Issued | ANTHONY EGSON |
| BUILDING-Rough-Frame | 6/4/2026 | Conditional Approval | HERBERT GIRON |
| ELECTRICAL-Rough | 6/4/2026 | Approved | HERBERT GIRON |
| Green Building Rough | 6/4/2026 | Approved | HERBERT GIRON |
| HVAC-Rough | 6/4/2026 | Approved | HERBERT GIRON |
| Interior/Exterior Lathing | 6/16/2026 | Partial Approval | HERBERT GIRON |
| BUILDING-Rough-Frame | 6/23/2026 | Approved | HERBERT GIRON |
| Insulation | 6/23/2026 | Approved | HERBERT GIRON |
| Drywall Nailing | 7/8/2026 | Approved | HERBERT GIRON |
| Interior/Exterior Lathing | 7/13/2026 | Approved | HERBERT GIRON |