380 WORLD WAY 90045

Certificate Information: 380 WORLD WAY 90045

Application / Permit
25016-10000-26505
Plan Check / Job No.
B25LA36811
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Commercial
Primary Use
(3) Airport Building
Work Description
IOS: Demolish existing BHS conveyors at TBIT L2 and bridge above L1 Bag Claim; install new oversize conveyors. Reframe L2 doghouse for new fire/security shutter. Build inclined BHS descent to L1 Bag Claim. Provide phenolic wall panels, stainless steel base, and revised wayfinding signage. DOS: Remove lockers and relocate agent counters at TBIT L1 Lobby. Demolish stair/doors to CBP; build new retaining/partition walls. Install terrazzo flooring, phenolic panels, and new domestic oversize bag claim belt along north wall. DR-1: Relocate egress Herculite door south; remove/reconfigure podium counters with queuing stanchions. Loaders: Demolish mens restroom at L1; rebuild east with same fixture count. Relocate janitors room and fountains.
Permit Issued
Issued on 4/10/2026
Issuing Office
Metro
Current Status
Issued on 4/10/2026

Permit Application Status History

Submitted 10/6/2025 APPLICANT
Assigned to Plan Check Engineer 10/9/2025 FARSHAD ALIMOHAMADI
Corrections Issued 10/21/2025 FARSHAD ALIMOHAMADI
Quality Review Completed 10/29/2025 EDUARDO RODRIGUEZ
Applicant returned to address corrections 4/3/2026 FARSHAD ALIMOHAMADI
Applicant returned to address corrections 4/7/2026 FARSHAD ALIMOHAMADI
Plan Check Approved 4/8/2026 FARSHAD ALIMOHAMADI
Issued 4/10/2026 APPLICANT

Permit Application Clearance Information

City owned building/parcel Cleared 10/30/2025 MASON NG
Project Permit Cleared 11/13/2025 FARSHAD ALIMOHAMADI
Green Code Cleared 12/5/2025 Eduardo Rodriguez
DAS Clearance Cleared 12/9/2025 Eduardo Rodriguez
Airport buildings Cleared 12/26/2025 ANDREW KO

Contact Information

Architect Rivers,, Steven Ramsey; Lic. No.: NA8068       ,
Contractor Owner-Builder       ,
Engineer Nadal,, Mark; Lic. No.: NA5494       ,

Inspector Information

DANIEL ARMENTA, (310) 914-3925 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

No Data Available.