706 W LOOKOUT DR 90012
Certificate Information: 706 W LOOKOUT DR 90012
- Application / Permit
- 25016-10000-13646
- Plan Check / Job No.
- X25LA17086
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (2) Duplex
- Work Description
- Re-roof with Class A or B material weighing less than 6 pounds per sq. ft. over existing solid sheathing 28 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone (VHFHSZ). For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council (CRRC). Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0(b) 2B.
- Permit Issued
- Issued on 4/29/2025
- Issuing Office
- South Los Angeles
- Current Status
- Permit Finaled on 1/12/2026
Permit Application Status History
| Issued | 4/29/2025 | APPLICANT |
| Permit Finaled | 1/8/2026 | FREDDIE RIVERA |
Permit Application Clearance Information
| No Data Available. |
Contact Information
| Contractor | Angel General Construction; Lic. No.: 815265-B | 447 WEST 93 RD STREET LOS ANGELES, CA 90003 |
Inspector Information
| HAMIK HARTOUNIAN, (213) 202-3275 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Floor/Roof Diaphrgm/Shear Wall | 5/8/2025 | Approved | ALEX COLIN |
| Final | 10/21/2025 | Corrections Issued | BRENDAN MORELLI |
| SGSOV-Seismic Gas S/O Valve | 10/21/2025 | SGSOV Not Ready | BRENDAN MORELLI |
| Smoke Detectors | 10/21/2025 | No Access for Inspection | BRENDAN MORELLI |
| Final | 11/14/2025 | Corrections Issued | HAMIK HARTOUNIAN |
| SGSOV-Seismic Gas S/O Valve | 11/14/2025 | SGSOV Not Ready | HAMIK HARTOUNIAN |
| Smoke Detectors | 11/14/2025 | Corrections Issued | HAMIK HARTOUNIAN |
| Final | 1/5/2026 | Not Ready for Inspection | HAMIK HARTOUNIAN |
| SGSOV-Seismic Gas S/O Valve | 1/5/2026 | SGSOV Not Ready | HAMIK HARTOUNIAN |
| Smoke Detectors | 1/5/2026 | Approved | HAMIK HARTOUNIAN |
| Final | 1/8/2026 | Permit Finaled | FREDDIE RIVERA |
| SGSOV-Seismic Gas S/O Valve | 1/8/2026 | SGSOV Approved | FREDDIE RIVERA |