4251 W BURNS AVE 90029
Certificate Information: 4251 W BURNS AVE 90029
- Application / Permit
- 25016-10000-12060
- Plan Check / Job No.
- B25LA15256
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (5) Apartment
- Work Description
- Eplan: Soft-Story Seismic Retrofit per LABC Chapter 93: SEISMIC RETROFIT ADD (N)-(1) SPECIAL CANTILEVERED COLUMN
- Permit Issued
- Issued on 7/25/2025
- Issuing Office
- Current Status
- CofC Issued on 5/19/2026
Permit Application Status History
| Submitted | 4/17/2025 | APPLICANT |
| Assigned to Plan Check Engineer | 4/24/2025 | BIDYUT RATH |
| Corrections Issued | 4/30/2025 | BIDYUT RATH |
| Quality Review Completed | 5/8/2025 | HANS SANTIAGO |
| Applicant returned to address corrections | 5/22/2025 | BIDYUT RATH |
| Plan Check Approved | 6/16/2025 | BIDYUT RATH |
| Issued | 7/25/2025 | APPLICANT |
| OK for CofC | 5/19/2026 | DARRYL ARNOLD |
| CofC Issued | 5/19/2026 | RAFAEL ESPINOZA |
Permit Application Clearance Information
| Tenant Habitability Plan | Cleared | 7/16/2025 | KORNEL LELEA |
Contact Information
| Contractor | Titan Contracting Services Inc; Lic. No.: 976552-B | 13434 RAYMER STREET NORTH HOLLYWOOD, CA 91605 |
| Engineer | Ding,, Wenzhuo; Lic. No.: C82891 | 5205 SUNNY POINT PL RANCHO PALOS VERDES, CA 90275 |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Drilled-In Anchors | 8/25/2025 | Conditional Approval | DARRYL ARNOLD |
| Deputy Reinf. Concrete | 8/25/2025 | Partial Approval | DARRYL ARNOLD |
| Deputy Steel/Welding | 8/25/2025 | Conditional Approval | DARRYL ARNOLD |
| Footing/Foundation/Slab | 8/27/2025 | Conditional Approval | DARRYL ARNOLD |
| Wood Frame | 8/27/2025 | Conditional Approval | DARRYL ARNOLD |
| Interior/Exterior Lathing | 9/3/2025 | Partial Approval | LUIS CCAMACHO |
| Final | 9/12/2025 | Not Ready for Inspection | DARRYL ARNOLD |
| SGSOV-Seismic Gas S/O Valve | 9/12/2025 | SGSOV Not Ready | DARRYL ARNOLD |
| Smoke Detectors | 9/12/2025 | Corrections Issued | DARRYL ARNOLD |
| Structural Steel Frame | 2/6/2026 | Approved | DARRYL ARNOLD |
| Final | 2/10/2026 | Conditional Approval | DARRYL ARNOLD |
| SGSOV-Seismic Gas S/O Valve | 2/10/2026 | SGSOV Approved | DARRYL ARNOLD |
| Smoke Detectors | 2/10/2026 | Approved | DARRYL ARNOLD |
| Final | 5/19/2026 | OK for CofC | DARRYL ARNOLD |