16660 W CUMBRE VERDE CT 90272

Certificate Information: 16660 W CUMBRE VERDE CT 90272

Application / Permit
25014-30000-01521
Plan Check / Job No.
B25WL02746
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
2025 WILDFIRE REBUILD, SINGLE-FAMILY DWELLING WITH AN ATTACHED GARAGE, (2)-STORY. NFPA 13D SPRINKLERS THROUGHOUT. TYPE VA MAINTAIN PORTION OF EXISTING FDN
Permit Issued
Issued on 9/23/2025
Issuing Office
Current Status
Issued on 9/23/2025
Certificate of Occupancy
Pending More Information

Permit Application Status History

Submitted 4/7/2025 APPLICANT
Assigned to Plan Check Engineer 4/8/2025 SERGIO SILVA
Corrections Issued 4/21/2025 SERGIO SILVA
Quality Review Completed 4/22/2025 CHIHARU SUZUKI
Building Plans Picked Up 4/22/2025 APPLICANT
Applicant returned to address corrections 5/13/2025 SERGIO SILVA
Applicant returned to address corrections 8/18/2025 SERGIO SILVA
Applicant returned to address corrections 9/4/2025 SERGIO SILVA
Plan Check Approved 9/11/2025 SERGIO SILVA
Plan Check Approved 9/11/2025 SERGIO SILVA
Issued 9/23/2025 APPLICANT

Permit Application Clearance Information

BHO/Hillside ordinance Cleared 4/25/2025 SAFA JAVANMARDI
Permit Cleared 4/25/2025 SAFA JAVANMARDI
Eng Process Fee Ord 176,300 Cleared 4/29/2025 SAFA JAVANMARDI
Sewer availability Cleared 4/29/2025 SAFA JAVANMARDI
Roof/Waste drainage to street Cleared 7/11/2025 DAVID LOPEZ
Low Impact Development (LID) Cleared 8/11/2025 MARTIN FRAGOSO
Watercourse Cleared 8/12/2025 HISASHI KOBAYAKAWA
Hydrant and Access approval Cleared 8/18/2025 KURT CORRAL

Contact Information

Contractor H L A Construction Inc; Lic. No.: 986853-B 5901 COLFAX AVE      NORTH HOLLYWOOD, CA 91601
Engineer De, Leon, Cynthia Aguilar; Lic. No.: C31604 347 ROBERTSON BLVD      BEVERLY HILLS, CA 90211
Engineer Kim,, Hong Kook; Lic. No.: C64529 3600 WILSHIRE BLVD STE 1903      LOS ANGELES, CA 90010
Engineer Miller,, Karen Lynn; Lic. No.: GE2257 6634 VALJEAN AVENUE      VAN NUYS, CA 91406
Geologist Van, Meter, James L.; Lic. No.: EG2031 6634 VALJEAN AVE      VAN NUYS, CA 91406
Landscape Architect Jensen,, Peter Cassidy; Lic. No.: LA5663 2632 WILSHIRE BLVD #106      SANTA MONICA, CA 90403

Inspector Information

MICHAEL ALLEN, (310) 914-3886 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 11/4/2025 Partial Approval KENNETH NAGLE
PLUMBING-Rough 11/4/2025 Partial Approval KENNETH NAGLE
Footing/Foundation/Slab 11/12/2025 Partial Approval BOBBY KEY
Footing/Foundation/Slab 12/2/2025 Partial Approval BOBBY KEY
Footing/Foundation/Slab 12/9/2025 Partial Approval DANIEL VERA
Deputy Wood Construction 1/6/2026 Approved DANIEL VERA
Floor/Roof Diaphrgm/Shear Wall 1/6/2026 Partial Approval DANIEL VERA
Deputy Steel/Welding 1/20/2026 Conditional Approval BOBBY KEY
Floor/Roof Diaphrgm/Shear Wall 2/24/2026 Not Ready for Inspection DANIEL VERA
Floor/Roof Diaphrgm/Shear Wall 2/25/2026 Corrections Issued DANIEL VERA
FLOOD-Proofing Certificate 3/9/2026 Not Ready for Inspection DANIEL VERA
Green Building Rough 3/9/2026 Not Ready for Inspection DANIEL VERA
Structural Steel Frame 3/9/2026 Partial Approval DANIEL VERA
Verify Sprinkler Sign Off 3/9/2026 Not Ready for Inspection DANIEL VERA
Floor/Roof Diaphrgm/Shear Wall 3/19/2026 Corrections Issued DANIEL VERA
Shower Pan 3/27/2026 Not Ready for Inspection DANIEL VERA
Floor/Roof Diaphrgm/Shear Wall 4/1/2026 Not Ready for Inspection DANIEL VERA
PLUMBING-Rough 4/1/2026 Corrections Issued DANIEL VERA
Floor/Roof Diaphrgm/Shear Wall 4/7/2026 Partial Approval DANIEL VERA
Green Building Rough 4/8/2026 Partial Approval MICHAEL ALLEN
Interior/Exterior Lathing 4/8/2026 Partial Approval MICHAEL ALLEN
Verify Sprinkler Sign Off 4/8/2026 Not Ready for Inspection MICHAEL ALLEN
ELECTRICAL-Rough 4/9/2026 Corrections Issued DANIEL VERA
HVAC-Rough 4/9/2026 Not Ready for Inspection DANIEL VERA
Interior/Exterior Lathing 4/9/2026 Partial Approval DANIEL VERA
HVAC-Rough 4/13/2026 Approved BOBBY KEY
BUILDING-Rough-Frame 4/14/2026 Corrections Issued DANIEL VERA
Green Building Rough 4/14/2026 Not Ready for Inspection DANIEL VERA
Shower Pan 4/14/2026 Approved DANIEL VERA
Structural Steel Frame 4/14/2026 Conditional Approval DANIEL VERA
Verify Sprinkler Sign Off 4/14/2026 Approved DANIEL VERA
Interior/Exterior Lathing 4/27/2026 Partial Approval DANIEL VERA
BUILDING-Rough-Frame 5/1/2026 Conditional Approval DANIEL VERA
Interior/Exterior Lathing 5/1/2026 Partial Approval DANIEL VERA
Insulation 5/20/2026 Conditional Approval MICHAEL ALLEN
BUILDING-Rough-Frame 5/22/2026 Approved MICHAEL ALLEN
ELECTRICAL-Rough 5/22/2026 Approved MICHAEL ALLEN
Green Building Rough 5/22/2026 Approved MICHAEL ALLEN
Interior/Exterior Lathing 5/22/2026 Approved MICHAEL ALLEN
Drywall Nailing 6/2/2026 Conditional Approval MICHAEL ALLEN
Interior/Exterior Lathing 6/2/2026 Approved MICHAEL ALLEN