6547-6549 N SATSUMA AVE 91606

Certificate Information: 6547-6549 N SATSUMA AVE 91606

Application / Permit
25014-20000-05121
Plan Check / Job No.
B25VN33859
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
FIRST FLOOR ADDITION AND CONVERT EXISTING ATTACHED GARAGE INTO ACCESSORY DWELLING UNIT PER LAMC 12.22.A.33 (a) AND (c) WITH A SECOND FLOOR ADDITION OF A SINGLE FAMILY DWELLING PER SB9 TO CREATE A DUPLEX WITH THE EXISTING SINGLE FAMILY DWELLING *NFPA-13D FIRE SPRINKLERED THROUGHOUT
Permit Issued
Issued on 1/27/2026
Issuing Office
Current Status
Issued on 1/27/2026
Certificate of Occupancy
Pending More Information

Permit Application Status History

Submitted 11/18/2025 APPLICANT
Assigned to Zoning Architect 11/20/2025 NICHOLE MACOY
Assigned to Plan Check Engineer 11/25/2025 DANIEL ABRAMYAN
Corrections Issued 11/30/2025 DANIEL ABRAMYAN
Quality Review Completed 12/1/2025 OMID HEDAYAT
Building Plans Picked Up 12/2/2025 APPLICANT
Plan Check Approved 1/12/2026 DANIEL ABRAMYAN
Issued 1/27/2026 APPLICANT

Permit Application Clearance Information

Address approval Cleared 12/17/2025 TONY CHIANG
Eng Process Fee Ord 176,300 Cleared 12/18/2025 TONY CHIANG
Sewer availability Cleared 12/18/2025 TONY CHIANG
Roof/Waste drainage to street Cleared 12/29/2025 TONY CHIANG
Senate Bill 9 Cleared 1/8/2026 ASHLEY MACIAS
Zoning Plan Check Cleared 1/12/2026 NICHOLE MACOY

Contact Information

Contractor Owner-Builder       ,
Engineer Grigoryan,, Souren; Lic. No.: C93320 6506 TEESDALE AVE      NORTH HOLLYWOOD, CA 91606

Inspector Information

GAREN HAYRAPETYAN, (818) 374-1171 Office Hours: 7:00-8:00 AM MON-FRI
ROBERTO PALACIOS-LOPEZ, (818) 374-1171 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

PLUMBING-Rough 3/2/2026 Partial Approval GAREN HAYRAPETYAN
Special/Order Compliance 3/2/2026 Corrections Issued GAREN HAYRAPETYAN
Underground Mechanical 3/2/2026 Partial Approval GAREN HAYRAPETYAN
Deputy Drilled-In Anchors 3/4/2026 Conditional Approval RAUL OLAGI
Excavation/Setback/Form/Re-Bar 3/5/2026 Approved RAUL OLAGI
Footing/Foundation/Slab 3/5/2026 Approved RAUL OLAGI
Floor/Roof Diaphrgm/Shear Wall 3/20/2026 Partial Inspection GAREN HAYRAPETYAN
Floor/Roof Diaphrgm/Shear Wall 4/2/2026 Partial Approval GAREN HAYRAPETYAN
Floor/Roof Diaphrgm/Shear Wall 4/21/2026 Partial Approval GAREN HAYRAPETYAN
Special/Order Compliance 4/21/2026 Corrections Issued GAREN HAYRAPETYAN
PLUMBING-Rough 5/12/2026 Approved GAREN HAYRAPETYAN
Floor/Roof Diaphrgm/Shear Wall 5/15/2026 Partial Approval GAREN HAYRAPETYAN
Special/Order Compliance 5/15/2026 Corrections Issued GAREN HAYRAPETYAN
ELECTRICAL-Rough 5/27/2026 Conditional Approval GAREN HAYRAPETYAN
HVAC-Rough 5/27/2026 Approved GAREN HAYRAPETYAN
Shower Pan 5/27/2026 Approved GAREN HAYRAPETYAN
Interior/Exterior Lathing 6/8/2026 Partial Approval GAREN HAYRAPETYAN
Special/Order Compliance 6/16/2026 Approved GAREN HAYRAPETYAN
Wood Frame 6/16/2026 Approved GAREN HAYRAPETYAN
Insulation 6/23/2026 Approved GAREN HAYRAPETYAN
Drywall Nailing 7/7/2026 Approved ROBERTO PALACIOS-LOPEZ
Green Building Rough 7/7/2026 Approved ROBERTO PALACIOS-LOPEZ