23426 W BERDON ST 91367
Certificate Information: 23426 W BERDON ST 91367
- Application / Permit
- 25014-20000-01950
- Plan Check / Job No.
- B25VN12396
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- eplan. Remodel of existing single family dwelling with attached garage. Rear addition for covered patio
- Permit Issued
- Issued on 6/3/2025
- Issuing Office
- Current Status
- Issued on 6/3/2025
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 5/3/2025 | APPLICANT |
| Assigned to Plan Check Engineer | 5/6/2025 | ADAM HEGAZI |
| Corrections Issued | 5/6/2025 | ADAM HEGAZI |
| Plan Check Approved | 5/27/2025 | ADAM HEGAZI |
| Issued | 6/3/2025 | APPLICANT |
Permit Application Clearance Information
| Grading Pre-Inspection | Cleared | 5/9/2025 | MANUEL TEJADA |
| Roof/Waste drainage to street | Cleared | 5/10/2025 | BRYAN GODINEZ |
| Eng Process Fee Ord 176,300 | Cleared | 5/12/2025 | BRYAN GODINEZ |
Contact Information
| Contractor | Dhs Ventures Inc; Lic. No.: 1047699-B | , |
| Contractor | La Ccs; Lic. No.: 1047699-B | , |
| Engineer | Southerland,, Richard Charles; Lic. No.: C88965 | 2335 E COLORADO BLVD SUITE 115, # 170 PASADENA, CA 91107 |
Inspector Information
| GEVORK IPCHYAN, (818) 774-4308 | Office Hours: 7:00-8:00 AM MON-FRI |
| TROY SANDERS, (818) 774-4308 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Drilled-In Anchors | 7/11/2025 | Conditional Approval | GEVORK IPCHYAN |
| Excavation/Setback/Form/Re-Bar | 7/11/2025 | Corrections Issued | GEVORK IPCHYAN |
| Excavation/Setback/Form/Re-Bar | 7/23/2025 | No Access for Inspection | TROY SANDERS |
| Excavation/Setback/Form/Re-Bar | 7/25/2025 | Approved | GEVORK IPCHYAN |
| BUILDING-Rough-Frame | 8/27/2025 | Not Ready for Inspection | GEVORK IPCHYAN |
| Green Building Rough | 8/27/2025 | Not Ready for Inspection | GEVORK IPCHYAN |
| Floor/Roof Diaphrgm/Shear Wall | 9/9/2025 | Corrections Issued | GEVORK IPCHYAN |
| BUILDING-Rough-Frame | 10/20/2025 | Partial Approval | GEVORK IPCHYAN |
| ELECTRICAL-Rough | 10/20/2025 | Approved | GEVORK IPCHYAN |
| Green Building Rough | 10/20/2025 | Not Ready for Inspection | GEVORK IPCHYAN |
| PLUMBING-Rough | 10/20/2025 | Not Ready for Inspection | GEVORK IPCHYAN |
| BUILDING-Rough-Frame | 10/24/2025 | Approved | GEVORK IPCHYAN |
| Floor/Roof Diaphrgm/Shear Wall | 10/24/2025 | Partial Approval | GEVORK IPCHYAN |
| Green Building Rough | 10/24/2025 | Approved | GEVORK IPCHYAN |
| Insulation | 10/24/2025 | Approved | GEVORK IPCHYAN |
| Interior/Exterior Lathing | 10/24/2025 | Partial Approval | GEVORK IPCHYAN |
| PLUMBING-Rough | 10/24/2025 | Approved | GEVORK IPCHYAN |
| Interior/Exterior Lathing | 10/27/2025 | Not Ready for Inspection | GEVORK IPCHYAN |
| Shower Pan | 10/28/2025 | Approved | GEVORK IPCHYAN |
| Interior/Exterior Lathing | 10/31/2025 | Approved | GEVORK IPCHYAN |
| Drywall Nailing | 11/17/2025 | Approved | GEVORK IPCHYAN |
| Final | 4/20/2026 | Not Ready for Inspection | GEVORK IPCHYAN |
| Footing/Foundation/Slab | 4/20/2026 | Approved | GEVORK IPCHYAN |
| Green Building Final | 4/20/2026 | Approved | GEVORK IPCHYAN |
| SGSOV-Seismic Gas S/O Valve | 4/20/2026 | SGSOV Approved | GEVORK IPCHYAN |
| Smoke Detectors | 4/20/2026 | Approved | GEVORK IPCHYAN |
| Final | 6/1/2026 | No Access for Inspection | TROY SANDERS |
| Final | 6/5/2026 | No Result Entered | GEVORK IPCHYAN |