831 N TEAKWOOD ROAD 90049

Certificate Information: 831 N TEAKWOOD ROAD 90049

Application / Permit
25014-20000-01589
Plan Check / Job No.
B25VN09965
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
ADD 74'-6" X 31'-2" IRREGULAR SHAPED ADDITION TO EXISTING SINGLE FAMILY DWELLING WITH ATTACHED GARAGE; EQUIPPED WITH NFPA 13-D FIRE SPRINKLERS THROUGHOUT
Permit Issued
Issued on 5/6/2025
Issuing Office
Current Status
CofO Issued on 6/11/2026
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 4/10/2025 APPLICANT
Assigned to Plan Check Engineer 4/17/2025 SELLA BENYAMIN
Corrections Issued 4/22/2025 SELLA BENYAMIN
Quality Review Completed 4/24/2025 STEVEN KIM
Building Plans Picked Up 4/24/2025 APPLICANT
Plan Check Approved 5/6/2025 SELLA BENYAMIN
Issued 5/6/2025 APPLICANT
CofO in Progress 6/2/2026 KEVIN SARGSYAN
Permit Finaled 6/11/2026 RICHARD STEINBACH
CofO Issued 6/11/2026 RICHARD STEINBACH
Permit Finaled 6/11/2026 RICHARD STEINBACH

Permit Application Clearance Information

BHO/Hillside ordinance Cleared 4/28/2025 LEE GUILBEAUX
BHO/Hillside ordinance Cleared 4/28/2025 LEE GUILBEAUX
BHO/Hillside ordinance Cleared 4/28/2025 LEE GUILBEAUX
BHO/Hillside ordinance Cleared 4/28/2025 LEE GUILBEAUX
Roof/Waste drainage to street Cleared 4/28/2025 LEE GUILBEAUX
Sewer availability Cleared 4/28/2025 LEE GUILBEAUX
Eng Process Fee Ord 176,300 Cleared 4/29/2025 LEE GUILBEAUX

Contact Information

Contractor Owner-Builder       ,
Engineer Sivushenka,, Mikita; Lic. No.: C87698 22814 DOLOROSA ST      WOODLAND HILLS, CA 91367

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Underground Mechanical 6/13/2025 Corrections Issued KEVIN SARGSYAN
Underground Mechanical 6/20/2025 Approved TEMISTOCLES CAAL
Footing/Foundation/Slab 6/27/2025 Partial Approval ARAM AVEDISIAN
Floor/Roof Diaphrgm/Shear Wall 7/29/2025 Corrections Issued KEVIN SARGSYAN
ELECTRICAL-Rough 9/17/2025 Corrections Issued KEVIN SARGSYAN
Floor/Roof Diaphrgm/Shear Wall 9/17/2025 Partial Approval KEVIN SARGSYAN
PLUMBING-Rough 9/17/2025 Partial Approval KEVIN SARGSYAN
Deputy Wood Construction 9/18/2025 Conditional Approval KEVIN SARGSYAN
Deputy Wood Construction 9/19/2025 No Access for Inspection KEVIN SARGSYAN
ELECTRICAL-Rough 10/1/2025 Approved KEVIN SARGSYAN
Floor/Roof Diaphrgm/Shear Wall 10/1/2025 Approved KEVIN SARGSYAN
Footing/Foundation/Slab 10/1/2025 Not Ready for Inspection KEVIN SARGSYAN
HVAC-Rough 10/1/2025 Approved KEVIN SARGSYAN
PLUMBING-Rough 10/1/2025 Approved KEVIN SARGSYAN
Interior/Exterior Lathing 10/14/2025 Partial Approval KEVIN SARGSYAN
Shower Pan 10/14/2025 Corrections Issued KEVIN SARGSYAN
BUILDING-Rough-Frame 10/15/2025 Corrections Issued KEVIN SARGSYAN
FLOOD-Proofing Certificate 10/15/2025 Approved KEVIN SARGSYAN
Footing/Foundation/Slab 10/15/2025 Approved KEVIN SARGSYAN
Green Building Rough 10/15/2025 Approved KEVIN SARGSYAN
Verify Sprinkler Sign Off 10/15/2025 Approved KEVIN SARGSYAN
BUILDING-Rough-Frame 10/22/2025 Not Ready for Inspection KEVIN SARGSYAN
Shower Pan 10/22/2025 Not Ready for Inspection KEVIN SARGSYAN
BUILDING-Rough-Frame 10/23/2025 Approved KEVIN SARGSYAN
Shower Pan 10/23/2025 Approved KEVIN SARGSYAN
Insulation 10/28/2025 Approved KEVIN SARGSYAN
Interior/Exterior Lathing 11/3/2025 Approved KEVIN SARGSYAN
Drywall Nailing 11/6/2025 Approved KEVIN SARGSYAN
ELECTRICAL-Final 5/20/2026 Corrections Issued KEVIN SARGSYAN
Final 5/20/2026 Corrections Issued KEVIN SARGSYAN
Green Building Final 5/20/2026 Approved KEVIN SARGSYAN
HVAC-Final 5/20/2026 Corrections Issued KEVIN SARGSYAN
PLUMBING-Final 5/20/2026 Corrections Issued KEVIN SARGSYAN
SGSOV-Seismic Gas S/O Valve 5/20/2026 SGSOV Not Ready KEVIN SARGSYAN
Service/Power Release 5/20/2026 Not Ready for Inspection KEVIN SARGSYAN
Smoke Detectors 5/20/2026 Approved KEVIN SARGSYAN
ELECTRICAL-Final 5/27/2026 Approved KEVIN SARGSYAN
Final 5/27/2026 Not Ready for Inspection KEVIN SARGSYAN
HVAC-Final 5/27/2026 Approved KEVIN SARGSYAN
PLUMBING-Final 5/27/2026 Not Ready for Inspection KEVIN SARGSYAN
SGSOV-Seismic Gas S/O Valve 5/27/2026 SGSOV Not Ready KEVIN SARGSYAN
Service/Power Release 5/27/2026 Approved KEVIN SARGSYAN
Final 6/2/2026 OK to Issue CofO KEVIN SARGSYAN
PLUMBING-Final 6/2/2026 Approved KEVIN SARGSYAN
SGSOV-Seismic Gas S/O Valve 6/2/2026 SGSOV Approved KEVIN SARGSYAN