12232 W CANTARA ST 91605

Certificate Information: 12232 W CANTARA ST 91605

Application / Permit
25014-20000-00296
Plan Check / Job No.
B25VN00450
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
Eplan: Convert existing garage with addition into Irregular shape (38'-6" x 22'-9") ADU per LAMC 12.22 A.33(b)(1)
Permit Issued
Issued on 6/12/2025
Issuing Office
Current Status
CofO Issued on 12/12/2025
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 1/8/2025 APPLICANT
Assigned to Plan Check Engineer 1/16/2025 EDWARD MEHRABIAN
Corrections Issued 1/23/2025 EDWARD MEHRABIAN
Quality Review Completed 1/31/2025 OMID HEDAYAT
Applicant returned to address corrections 2/27/2025 EDWARD MEHRABIAN
Applicant returned to address corrections 3/3/2025 EDWARD MEHRABIAN
Applicant returned to address corrections 3/12/2025 EDWARD MEHRABIAN
Plan Check Approved 6/12/2025 EDWARD MEHRABIAN
Issued 6/12/2025 APPLICANT
CofO in Progress 11/19/2025 MATTHEW NELSON
Permit Finaled 12/12/2025 RUBEN SALAS
CofO Issued 12/12/2025 RUBEN SALAS
Permit Finaled 12/12/2025 RUBEN SALAS

Permit Application Clearance Information

Address approval Cleared 2/11/2025 BIAINA HARITUNIAN
Roof/Waste drainage to street Cleared 2/11/2025 BIAINA HARITUNIAN
Eng Process Fee Ord 176,300 Cleared 2/13/2025 BIAINA HARITUNIAN
Sewer availability Cleared 2/13/2025 BIAINA HARITUNIAN
Hydrant and Access approval Cleared 2/20/2025 PATRICK PEREZ
Construction within easement Cleared 3/21/2025 GEVORK KARAPETYAN

Contact Information

Contractor Owner-Builder       ,
Engineer Burnazyan,, Gegam; Lic. No.: C76761 3625 BEVERLY RIDGE DRIVE      SHERMAN OAKS, CA 91423

Inspector Information

MATTHEW NELSON, (818) 374-1170 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Underground Mechanical 7/18/2025 Not Ready for Inspection MICHAEL CORTEZ
Underground Mechanical 7/21/2025 Approved MATTHEW NELSON
Deputy Drilled-In Anchors 7/24/2025 Conditional Approval DAVID MATSON
Footing/Foundation/Slab 7/28/2025 Approved MATTHEW NELSON
BUILDING-Rough-Frame 8/29/2025 Corrections Issued MATTHEW NELSON
ELECTRICAL-Rough 8/29/2025 Approved MATTHEW NELSON
Floor/Roof Diaphrgm/Shear Wall 8/29/2025 Approved MATTHEW NELSON
Green Building Rough 8/29/2025 Not Ready for Inspection MATTHEW NELSON
HVAC-Rough 8/29/2025 Approved MATTHEW NELSON
PLUMBING-Rough 8/29/2025 Approved MATTHEW NELSON
BUILDING-Rough-Frame 9/4/2025 Approved MATTHEW NELSON
Green Building Rough 9/4/2025 Approved MATTHEW NELSON
Interior/Exterior Lathing 9/4/2025 Partial Approval MATTHEW NELSON
Shower Pan 9/4/2025 Approved MATTHEW NELSON
Underground Mechanical 9/4/2025 Approved MATTHEW NELSON
Floor/Roof Diaphrgm/Shear Wall 9/9/2025 Approved MATTHEW NELSON
Insulation 9/9/2025 Approved MATTHEW NELSON
Drywall Nailing 9/19/2025 Not Ready for Inspection WILLIAM WREN
Drywall Nailing 9/26/2025 Approved MICHAEL CORTEZ
Underground Mechanical 10/1/2025 Approved MATTHEW NELSON
Interior/Exterior Lathing 10/14/2025 Approved MATTHEW NELSON
ELECTRICAL-Final 11/14/2025 Approved OGANES TARAKHCHYAN
HVAC-Final 11/14/2025 Approved OGANES TARAKHCHYAN
PLUMBING-Final 11/14/2025 Approved OGANES TARAKHCHYAN
Final 11/18/2025 OK to Issue CofO MATTHEW NELSON
Green Building Final 11/18/2025 Approved MATTHEW NELSON
SGSOV-Seismic Gas S/O Valve 11/18/2025 SGSOV Approved MATTHEW NELSON
Service/Power Release 11/18/2025 Approved MATTHEW NELSON
Smoke Detectors 11/18/2025 Approved MATTHEW NELSON
Verify Rec and Parks Fee Memo 11/18/2025 Approved MATTHEW NELSON