22122 W COVELLO ST 91303
Certificate Information: 22122 W COVELLO ST 91303
- Application / Permit
- 25014-20000-00165
- Plan Check / Job No.
- B25VN00792
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- ePlan: Addition to single family dwelling to enlarge bedroom. Remodel kitchen area.
- Permit Issued
- Issued on 3/31/2025
- Issuing Office
- Current Status
- CofO Issued on 9/30/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 1/14/2025 | APPLICANT |
| Assigned to Plan Check Engineer | 1/21/2025 | MINA HABILI |
| Corrections Issued | 1/22/2025 | MINA HABILI |
| Plan Check Approved | 3/28/2025 | RICARDO RAMIREZ |
| Issued | 3/31/2025 | APPLICANT |
| CofO in Progress | 9/26/2025 | JEFFREY HARTLINE |
| Permit Finaled | 9/30/2025 | JOHN JANSON |
| CofO Issued | 9/30/2025 | JOHN JANSON |
| Permit Finaled | 9/30/2025 | JOHN JANSON |
Permit Application Clearance Information
| Roof/Waste drainage to street | Cleared | 2/5/2025 | LEE GUILBEAUX |
| Public Works-Highway Ded. | Cleared | 2/5/2025 | LEE GUILBEAUX |
| Eng Process Fee Ord 176,300 | Cleared | 2/25/2025 | LEE GUILBEAUX |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Espino,, Manuel A; Lic. No.: C55526 | 12109 WOODRUFF AVE DOWNEY, CA 90241 |
Inspector Information
| JEFFREY HARTLINE, (818) 774-4320 | Office Hours: 7:00-8:00 AM MON-FRI |
| CHRIS CHRISTENSEN, (818) 774-4320 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| PLUMBING-Rough | 4/14/2025 | Partial Approval | CHRIS CHRISTENSEN |
| Deputy Drilled-In Anchors | 4/17/2025 | Approved | CHRIS CHRISTENSEN |
| Footing/Foundation/Slab | 4/17/2025 | Approved | CHRIS CHRISTENSEN |
| Floor/Roof Diaphrgm/Shear Wall | 4/30/2025 | Partial Approval | CHRIS CHRISTENSEN |
| Underground Mechanical | 4/30/2025 | Partial Approval | CHRIS CHRISTENSEN |
| BUILDING-Rough-Frame | 5/2/2025 | Partial Approval | CHRIS CHRISTENSEN |
| ELECTRICAL-Rough | 5/2/2025 | Approved | CHRIS CHRISTENSEN |
| Green Building Rough | 5/2/2025 | Not Ready for Inspection | CHRIS CHRISTENSEN |
| PLUMBING-Rough | 5/2/2025 | Approved | CHRIS CHRISTENSEN |
| Underground Mechanical | 5/2/2025 | Partial Approval | CHRIS CHRISTENSEN |
| BUILDING-Rough-Frame | 5/7/2025 | Approved | CHRIS CHRISTENSEN |
| Green Building Rough | 5/7/2025 | Approved | CHRIS CHRISTENSEN |
| Interior/Exterior Lathing | 5/7/2025 | Partial Approval | CHRIS CHRISTENSEN |
| Insulation | 5/8/2025 | Approved | CHRIS CHRISTENSEN |
| Drywall Nailing | 5/13/2025 | Approved | CHRIS CHRISTENSEN |
| Interior/Exterior Lathing | 5/13/2025 | Approved | CHRIS CHRISTENSEN |
| Shower Pan | 5/13/2025 | Approved | CHRIS CHRISTENSEN |
| Service/Power Release | 6/25/2025 | Corrections Issued | CHRIS CHRISTENSEN |
| Service/Power Release | 7/16/2025 | No Access for Inspection | CHRIS CHRISTENSEN |
| Service/Power Release | 7/18/2025 | Approved | CHRIS CHRISTENSEN |
| Green Building Final | 9/9/2025 | Not Ready for Inspection | JEFFREY HARTLINE |
| SGSOV-Seismic Gas S/O Valve | 9/9/2025 | SGSOV Not Ready | JEFFREY HARTLINE |
| Smoke Detectors | 9/9/2025 | Not Ready for Inspection | JEFFREY HARTLINE |
| Final | 9/12/2025 | Corrections Issued | JEFFREY HARTLINE |
| Green Building Final | 9/12/2025 | Not Ready for Inspection | JEFFREY HARTLINE |
| SGSOV-Seismic Gas S/O Valve | 9/12/2025 | SGSOV Approved | JEFFREY HARTLINE |
| Smoke Detectors | 9/12/2025 | Approved | JEFFREY HARTLINE |
| Final | 9/19/2025 | Partial Approval | JEFFREY HARTLINE |
| Green Building Final | 9/19/2025 | Approved | JEFFREY HARTLINE |
| ELECTRICAL-Final | 9/23/2025 | Approved | JEFFREY HARTLINE |
| HVAC-Final | 9/23/2025 | Approved | JEFFREY HARTLINE |
| PLUMBING-Final | 9/23/2025 | Approved | JEFFREY HARTLINE |
| Final | 9/25/2025 | OK to Issue CofO | JEFFREY HARTLINE |