3616 S MOUNTAIN VIEW AVE 90066

Certificate Information: 3616 S MOUNTAIN VIEW AVE 90066

Application / Permit
25014-10000-04773
Plan Check / Job No.
B25LA45108
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
MAJOR REMODELING AND ADDITION TO (E) SFD WITH NEW ATTACHED GARAGE, AND ROOF DECK. WORK DONE PER ENGINEER DESIGN. ***13D SPRINKLER REQUIRED*** 1 OF 2
Permit Issued
Issued on 1/12/2026
Issuing Office
Metro
Current Status
Issued on 1/12/2026
Certificate of Occupancy
Pending More Information

Permit Application Status History

Submitted 10/27/2025 APPLICANT
Assigned to Plan Check Engineer 10/30/2025 KHUONG TRUONG
Assigned to Zoning Architect 10/30/2025 KAREN MEZA-MORALES
Corrections Issued 11/5/2025 KHUONG TRUONG
Quality Review Completed 11/7/2025 KEN GILL
Building Plans Picked Up 11/12/2025 APPLICANT
Applicant returned to address corrections 1/6/2026 KHUONG TRUONG
Plan Check Approved 1/12/2026 KHUONG TRUONG
Issued 1/12/2026 APPLICANT

Permit Application Clearance Information

Eng Process Fee Ord 176,300 Cleared 11/14/2025 BIAINA HARITUNIAN
Roof/Waste drainage to street Cleared 11/14/2025 BIAINA HARITUNIAN
Sewer availability Cleared 11/14/2025 BIAINA HARITUNIAN
Miscellaneous Cleared 11/19/2025 GEORGIA SMITH
Miscellaneous Cleared 11/19/2025 GEORGIA SMITH
Grading Pre-Inspection Cleared 12/1/2025 MANUEL TEJADA
Specific Plan Cleared 12/11/2025 EDER ROMERO
Zoning Plan Check Cleared 1/5/2026 KAREN MEZA-MORALES
GPI Written Notices Cleared 1/6/2026 KHUONG TRUONG

Contact Information

Contractor Owner-Builder       ,
Engineer Khatchadourian,, Vicken; Lic. No.: S3141 1221 N CEDAR ST      GLENDALE, CA 92107

Inspector Information

KIRK SANDERS, (310) 914-3896 Office Hours: 7:00-8:00 AM MON-FRI
ARAM AVEDISIAN, (310) 914-3896 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

PLUMBING-Rough 6/9/2026   

Inspection Request History

Footing/Foundation/Slab 1/23/2026 Partial Approval ARAM AVEDISIAN
PLUMBING-Rough 1/23/2026 Partial Approval ARAM AVEDISIAN
Sewer 1/23/2026 Approved ARAM AVEDISIAN
Footing/Foundation/Slab 2/4/2026 Approved ARAM AVEDISIAN
Floor/Roof Diaphrgm/Shear Wall 3/12/2026 Partial Approval ARAM AVEDISIAN
Floor/Roof Diaphrgm/Shear Wall 4/8/2026 Partial Approval ANTHONY EGSON
Floor/Roof Diaphrgm/Shear Wall 5/7/2026 Corrections Issued EUGENE CASSIDY
Deputy Steel/Welding 5/22/2026 Conditional Approval KIRK SANDERS
Floor/Roof Diaphrgm/Shear Wall 5/26/2026 Conditional Approval KIRK SANDERS
HVAC-Rough 5/26/2026 Corrections Issued KIRK SANDERS
HVAC-Rough 6/3/2026 Approved ARAM AVEDISIAN
Underground Mechanical 6/3/2026 Partial Approval ARAM AVEDISIAN