5842 N ALDEA AVE 91316
Certificate Information: 5842 N ALDEA AVE 91316
- Application / Permit
- 25014-10000-02523
- Plan Check / Job No.
- B25LA22819
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- NEW 10'11" X 16'1" ADDITION TO AND REMODEL OF EXISTING SINGLE FAMILY DWELLING TO EXTEND MASTER BEDROOM, ADD NEW BATHROOM, AND ADD NEW OFFICE. WORK DONE PER ENGINEER DESIGN.
- Permit Issued
- Issued on 7/8/2025
- Issuing Office
- Current Status
- CofO Issued on 12/29/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 6/2/2025 | APPLICANT |
| Assigned to Plan Check Engineer | 6/5/2025 | MADISON ODELL |
| Corrections Issued | 6/6/2025 | MADISON ODELL |
| Applicant returned to address corrections | 6/30/2025 | MADISON ODELL |
| Plan Check Approved | 7/8/2025 | MADISON O'DELL |
| Issued | 7/8/2025 | APPLICANT |
| CofO in Progress | 12/23/2025 | JON MCHUGH |
| Permit Finaled | 12/29/2025 | JOHN JANSON |
| CofO Issued | 12/29/2025 | JOHN JANSON |
| Permit Finaled | 12/29/2025 | JOHN JANSON |
Permit Application Clearance Information
| Eng Process Fee Ord 176,300 | Cleared | 6/24/2025 | DERRICK MAGEE |
| Roof/Waste drainage to street | Cleared | 6/24/2025 | DERRICK MAGEE |
Contact Information
| Contractor | Ind Construction Llc; Lic. No.: 937833-B | , |
| Engineer | Shahbaz,, Shant Pierre; Lic. No.: NA93079 | , |
Inspector Information
| JON MCHUGH, (818) 774-4348 | Office Hours: 7:00-8:00 AM MON-FRI |
| IVAN SARABIA, (818) 774-4348 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Drilled-In Anchors | 8/25/2025 | Approved | JON MCHUGH |
| Footing/Foundation/Slab | 8/25/2025 | Corrections Issued | JON MCHUGH |
| Footing/Foundation/Slab | 8/28/2025 | Approved | JON MCHUGH |
| Floor/Roof Diaphrgm/Shear Wall | 9/3/2025 | Partial Approval | MORRIS JACKSON |
| Floor/Roof Diaphrgm/Shear Wall | 9/4/2025 | Partial Approval | JOHN HAYES |
| Floor/Roof Diaphrgm/Shear Wall | 9/15/2025 | Partial Approval | JON MCHUGH |
| PLUMBING-Rough | 9/15/2025 | Approved | JON MCHUGH |
| Deputy Wood Construction | 9/25/2025 | Conditional Approval | JON MCHUGH |
| ELECTRICAL-Rough | 9/29/2025 | Corrections Issued | JON MCHUGH |
| HVAC-Rough | 9/29/2025 | Corrections Issued | JON MCHUGH |
| Shower Pan | 9/29/2025 | Approved | JON MCHUGH |
| Wood Frame | 9/29/2025 | Not Ready for Inspection | JON MCHUGH |
| BUILDING-Rough-Frame | 10/6/2025 | Approved | TROY SANDERS |
| ELECTRICAL-Rough | 10/6/2025 | Partial Approval | TROY SANDERS |
| Green Building Rough | 10/6/2025 | Approved | TROY SANDERS |
| HVAC-Rough | 10/6/2025 | Approved | TROY SANDERS |
| Insulation | 10/6/2025 | Approved | TROY SANDERS |
| Interior/Exterior Lathing | 10/6/2025 | Approved | TROY SANDERS |
| Drywall Nailing | 10/9/2025 | Approved | JON MCHUGH |
| Final | 12/1/2025 | Corrections Issued | JON MCHUGH |
| Green Building Final | 12/1/2025 | Approved | JON MCHUGH |
| SGSOV-Seismic Gas S/O Valve | 12/1/2025 | SGSOV Approved | JON MCHUGH |
| Smoke Detectors | 12/1/2025 | Approved | JON MCHUGH |
| ELECTRICAL-Final | 12/22/2025 | Approved | JON MCHUGH |
| Final | 12/22/2025 | OK to Issue CofO | JON MCHUGH |
| HVAC-Final | 12/22/2025 | Approved | JON MCHUGH |
| PLUMBING-Final | 12/22/2025 | Approved | JON MCHUGH |