10530 W PUTNEY ROAD 90064
Certificate Information: 10530 W PUTNEY ROAD 90064
- Application / Permit
- 25014-10000-01307
- Plan Check / Job No.
- B25LA11426
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- EPLAN. CONVERT PORTION OF (E) GARAGE TO ADU AND ADDITION TO ADU TO BUILD A ........SF ADU. PER LAMC 12.22 A.33(b)(1)
- Permit Issued
- Issued on 1/11/2026
- Issuing Office
- Current Status
- Issued on 1/11/2026
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 3/26/2025 | APPLICANT |
| Assigned to Plan Check Engineer | 3/28/2025 | ALFREDO JARA |
| Corrections Issued | 3/29/2025 | ALFREDO JARA |
| Applicant returned to address corrections | 9/11/2025 | KAVIAN REFAHI |
| Plan Check Approved | 10/17/2025 | KAVIAN REFAHI |
| Issued | 1/11/2026 | APPLICANT |
Permit Application Clearance Information
| Address approval | Cleared | 4/9/2025 | SAFA JAVANMARDI |
| Eng Process Fee Ord 176,300 | Cleared | 4/12/2025 | SAFA JAVANMARDI |
| Roof/Waste drainage to street | Cleared | 4/12/2025 | SAFA JAVANMARDI |
| Grading Pre-Inspection | Cleared | 4/25/2025 | LANNY MERRICK |
| Sewer availability | Cleared | 4/26/2025 | SAFA JAVANMARDI |
| Specific Plan | Cleared | 6/16/2025 | PEDRO AYALA |
| Specific Plan | Cleared | 6/16/2025 | PEDRO AYALA |
| Construction near power lines | Cleared | 8/21/2025 | RIDWAN HARDY |
| GPI Written Notices | Cleared | 9/12/2025 | ALFREDO JARA |
Contact Information
| Contractor | Eberia Construction Inc; Lic. No.: 701330-B | , |
| Engineer | Yaprak,, Taskin Tolga; Lic. No.: C72927 | 562 31ST ST MANHATTAN BEACH, CA 90266 |
| Engineer | Yaprak,, Taskin Tolga; Lic. No.: NA72927 | , |
Inspector Information
| ASHLEY THOMPSON, (310) 914-3897 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| ELECTRICAL-Rough | 6/9/2026 |
| Underground Mechanical | 6/9/2026 |
Inspection Request History
| Underground Mechanical | 1/21/2026 | Approved | MICHAEL ALLEN |
| Excavation/Setback/Form/Re-Bar | 2/9/2026 | Approved | WILBER ROSALES |
| Footing/Foundation/Slab | 2/9/2026 | Approved | WILBER ROSALES |
| METHANE-Barrier | 2/9/2026 | Approved | WILBER ROSALES |
| METHANE-Subgrade | 2/9/2026 | Approved | WILBER ROSALES |
| Floor/Roof Diaphrgm/Shear Wall | 3/9/2026 | Corrections Issued | ASHLEY THOMPSON |
| Special/Order Compliance | 3/9/2026 | Corrections Issued | ASHLEY THOMPSON |
| Floor/Roof Diaphrgm/Shear Wall | 3/12/2026 | Partial Approval | ARAM AVEDISIAN |
| ELECTRICAL-Rough | 4/8/2026 | Approved | ASHLEY THOMPSON |
| HVAC-Rough | 4/8/2026 | Corrections Issued | ASHLEY THOMPSON |
| PLUMBING-Rough | 4/8/2026 | Approved | ASHLEY THOMPSON |
| Deputy Drilled-In Anchors | 4/30/2026 | Conditional Approval | HERBERT GIRON |
| Deputy Wood Construction | 4/30/2026 | Conditional Approval | DANIEL VERA |
| Floor/Roof Diaphrgm/Shear Wall | 5/8/2026 | Approved | ASHLEY THOMPSON |
| BUILDING-Rough-Frame | 5/19/2026 | Approved | WILBER ROSALES |
| Green Building Rough | 5/19/2026 | Approved | WILBER ROSALES |
| HVAC-Rough | 5/19/2026 | Approved | WILBER ROSALES |
| Interior/Exterior Lathing | 5/19/2026 | Partial Approval | WILBER ROSALES |
| METHANE-Rough | 5/19/2026 | Approved | WILBER ROSALES |
| Insulation | 6/1/2026 | Partial Approval | ARAM AVEDISIAN |