15747 W ADDISON ST 91436

Certificate Information: 15747 W ADDISON ST 91436

Application / Permit
25010-20000-04013
Plan Check / Job No.
B25VN25542
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(23) Patio Cover
Work Description
NEW 12' X 18' DETACHED PATIO COVER PER ENGINEERING
Permit Issued
Issued on 12/16/2025
Issuing Office
Current Status
Issued on 12/16/2025
Certificate of Occupancy
Pending More Information

Permit Application Status History

Submitted 9/2/2025 APPLICANT
Assigned to Plan Check Engineer 9/11/2025 RAPHAEL ROSAS
Assigned to Zoning Architect 9/11/2025 VAHE ZARUKIAN
Corrections Issued 9/23/2025 RAPHAEL ROSAS
Quality Review Completed 9/26/2025 STEVEN KIM
Building Plans Picked Up 9/30/2025 APPLICANT
Plan Check Approved 12/16/2025 RAPHAEL ROSAS
Issued 12/16/2025 APPLICANT

Permit Application Clearance Information

Eng Process Fee Ord 176,300 Cleared 10/16/2025 CELINA MORENO
Trees in Parkway Cleared 10/17/2025 RICHARD SANCHEZ
Low Impact Development (LID) Cleared 10/21/2025 ERNEST TSE
Roof/Waste drainage to street Cleared 11/1/2025 CELINA MORENO
Construction near power lines Cleared 11/6/2025 GEVORK KARAPETYAN
Frnt yard landscape/Water mgmt Cleared 11/13/2025 JAZMIN ROQUE
Zoning Plan Check Cleared 11/25/2025 VAHEN ZAKURIAN

Contact Information

Contractor Owner-Builder       ,
Engineer Wang,, Hongyu; Lic. No.: C72679 8887 W FALMINGO RD STE 101      LAS VEGAS, NV 89147

Inspector Information

THOMAS FINNILA, (818) 774-4324 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 1/8/2026 Not Ready for Inspection THOMAS FINNILA
Underground Mechanical 1/8/2026 Not Ready for Inspection THOMAS FINNILA
Footing/Foundation/Slab 1/12/2026 Conditional Approval JOHN KIDWELL
Footing/Foundation/Slab 1/15/2026 Approved THOMAS FINNILA
ELECTRICAL-Rough 3/16/2026 Approved SEAN WIRCH
Floor/Roof Diaphrgm/Shear Wall 3/16/2026 Approved SEAN WIRCH
PLUMBING-Rough 3/16/2026 Approved SEAN WIRCH
Underground Mechanical 3/16/2026 Approved SEAN WIRCH
Interior/Exterior Lathing 4/3/2026 Partial Approval JOHN KIDWELL