16701 W SUNSET BLVD 90272

Certificate Information: 16701 W SUNSET BLVD 90272

Application / Permit
25010-20000-01987
Plan Check / Job No.
B25VN12792
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
2025 WILDFIRE REBUILD, SINGLE-FAMILY DWELLING WITH AN ATTACHED GARAGE, (1)-STORY. NFPA 13D SPRINKLERS THROUGHOUT
Permit Issued
Issued on 7/15/2025
Issuing Office
Current Status
Issued on 7/15/2025
Certificate of Occupancy
Pending More Information

Permit Application Status History

Submitted 5/7/2025 APPLICANT
Assigned to Plan Check Engineer 5/8/2025 RAPHAEL ROSAS
Corrections Issued 5/12/2025 RAPHAEL ROSAS
Quality Review Completed 5/12/2025 STEVEN KIM
Building Plans Picked Up 5/13/2025 APPLICANT
Applicant returned to address corrections 6/10/2025 RAPHAEL ROSAS
Plan Check Approved 7/11/2025 RAPHAEL ROSAS
Issued 7/15/2025 APPLICANT

Permit Application Clearance Information

Eng Process Fee Ord 176,300 Cleared 5/22/2025 CINDY QI
Roof/Waste drainage to street Cleared 5/22/2025 CINDY QI
Sewer availability Cleared 5/22/2025 CINDY QI
Hydrant and Access approval Cleared 5/30/2025 JOHN CONNEALLY
Construction near power lines Cleared 7/1/2025 RIDWAN HARDY

Contact Information

Contractor Psg Construction Co; Lic. No.: 1079377-B 10418 GLADE AVENUE      CHATSWORTH, CA 91311
Engineer Kazemi,, Milad; Lic. No.: C92143 28025 DOROTHY DR STE 202      AGOURA HILLS, CA 91301

Inspector Information

DANIEL VERA, (213) 577-9924 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 7/22/2025 Partial Inspection STEPHANIE SWANSON
Grading Pre-Inspection 7/23/2025 No Access for Inspection BOBBY KEY
Pre-Inspection 7/23/2025 No Access for Inspection BOBBY KEY
Excavation/Setback/Form/Re-Bar 9/9/2025 Partial Approval BOBBY KEY
PLUMBING-Rough 9/12/2025 Corrections Issued BOBBY KEY
PLUMBING-Rough 9/22/2025 Partial Approval BOBBY KEY
Excavation/Setback/Form/Re-Bar 9/30/2025 Approved BOBBY KEY
Footing/Foundation/Slab 9/30/2025 Conditional Approval BOBBY KEY
PLUMBING-Rough 9/30/2025 Not Ready for Inspection BOBBY KEY
BUILDING-Rough-Frame 11/13/2025 Not Ready for Inspection MEL KHACHATOURIAN
Footing/Foundation/Slab 11/13/2025 Not Ready for Inspection MEL KHACHATOURIAN
Green Building Rough 11/13/2025 Not Ready for Inspection MEL KHACHATOURIAN
Verify Sprinkler Sign Off 11/13/2025 Not Ready for Inspection MEL KHACHATOURIAN
Wood Frame 11/13/2025 Not Ready for Inspection MEL KHACHATOURIAN
Floor/Roof Diaphrgm/Shear Wall 11/19/2025 Approved BOBBY KEY
Footing/Foundation/Slab 11/19/2025 Approved BOBBY KEY
ELECTRICAL-Rough 12/15/2025 Corrections Issued BOBBY KEY
HVAC-Rough 12/15/2025 Approved BOBBY KEY
PLUMBING-Rough 12/15/2025 Corrections Issued BOBBY KEY
ELECTRICAL-Rough 12/22/2025 Not Ready for Inspection DANIEL VERA
Interior/Exterior Lathing 12/22/2025 Not Ready for Inspection DANIEL VERA
ELECTRICAL-Rough 12/26/2025 Approved DANIEL VERA
Insulation 12/26/2025 Not Ready for Inspection DANIEL VERA
Interior/Exterior Lathing 12/26/2025 Partial Approval DANIEL VERA
BUILDING-Rough-Frame 12/30/2025 Conditional Approval BOBBY KEY
Green Building Rough 12/30/2025 Conditional Approval BOBBY KEY
Insulation 12/30/2025 Not Ready for Inspection BOBBY KEY
PLUMBING-Rough 12/30/2025 Approved BOBBY KEY
Verify Sprinkler Sign Off 12/30/2025 Approved BOBBY KEY
Insulation 3/16/2026 Approved BOBBY KEY
Interior/Exterior Lathing 3/16/2026 Partial Approval BOBBY KEY
Drywall Nailing 3/20/2026 Approved RYAN SALAZAR
Green Building Rough 3/20/2026 Approved RYAN SALAZAR
Shower Pan 3/20/2026 Approved RYAN SALAZAR
Gas Test 6/1/2026 Not Ready for Inspection DANIEL VERA