16780 W BOLLINGER DR 90272

Certificate Information: 16780 W BOLLINGER DR 90272

Application / Permit
25010-10000-03719
Plan Check / Job No.
B25LA34206
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
2025 WILDFIRE REBUILD, SINGLE-FAMILY DWELLING WITH AN ATTACHED GARAGE. NFPA 13D SPRINKLERS THROUGHOUT
Permit Issued
Issued on 12/11/2025
Issuing Office
Current Status
Issued on 12/11/2025
Certificate of Occupancy
Pending More Information

Permit Application Status History

Submitted 9/16/2025 APPLICANT
Assigned to Plan Check Engineer 9/18/2025 JOE VO
Corrections Issued 9/25/2025 JOE VO
Quality Review Completed 9/29/2025 GARO TELMI
Applicant returned to address corrections 11/20/2025 JOE VO
Plan Check Approved 12/9/2025 JOE VO
Issued 12/11/2025 APPLICANT

Permit Application Clearance Information

Eng Process Fee Ord 176,300 Cleared 9/29/2025 MICHAEL BROWN
Roof/Waste drainage to street Cleared 9/29/2025 MICHAEL BROWN
Sewer availability Cleared 9/29/2025 MICHAEL BROWN
Trees in Parkway Cleared 10/3/2025 RICHARD SANCHEZ
GPI Written Notices Cleared 12/1/2025 JOE VO
Hydrant and Access approval Cleared 12/8/2025 GILBERT URREA
Low Impact Development (LID) Cleared 12/8/2025 ERNEST TSE

Contact Information

Contractor Watt Palisades; Lic. No.: 694749-B       ,
Engineer Nikjoo,, Shahram; Lic. No.: C36969 6011 E BRIGHTON LANE      ANAHEIM, CA 92807

Inspector Information

DANIEL VERA, (213) 577-9924 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

HVAC-Rough 6/8/2026   

Inspection Request History

Pre-Inspection 1/6/2026 Partial Inspection BOBBY KEY
Excavation/Setback/Form/Re-Bar 3/4/2026 Partial Approval BOBBY KEY
Deputy Other (see comments) 3/6/2026 Conditional Approval JUAN VALENZUELA
Deputy Reinf. Concrete 3/6/2026 Conditional Approval JUAN VALENZUELA
Excavation/Setback/Form/Re-Bar 3/12/2026 Partial Approval BOBBY KEY
Underground Mechanical 3/19/2026 Partial Approval BOBBY KEY
Footing/Foundation/Slab 3/24/2026 Approved BOBBY KEY
Deputy Steel/Welding 4/8/2026 Conditional Approval JUAN VALENZUELA
Floor/Roof Diaphrgm/Shear Wall 4/15/2026 Partial Approval BOBBY KEY
Floor/Roof Diaphrgm/Shear Wall 4/28/2026 Not Ready for Inspection DANIEL VERA
Floor/Roof Diaphrgm/Shear Wall 5/14/2026 Corrections Issued DANIEL VERA
Floor/Roof Diaphrgm/Shear Wall 5/22/2026 Partial Approval DANIEL VERA