22344 W BALTAR ST 91304
Certificate Information: 22344 W BALTAR ST 91304
- Application / Permit
- 24047-20000-00565
- Plan Check / Job No.
- B24VN05698
- Group
- Building
- Type
- Swimming-Pool/Spa
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (20) Pool/Spa - Private
- Work Description
- REMODEL THE (E) POOL, REPLASTER, RELOCATE POOL EQUIPMENT AND SPLIT THE DRAIN PER STD PLAN No. 265 AND ENG DETAILS
- Permit Issued
- Issued on 5/2/2024
- Issuing Office
- Valley
- Current Status
- Permit Finaled on 10/31/2025
Permit Application Status History
| Submitted | 4/25/2024 | APPLICANT |
| Assigned to Plan Check Engineer | 4/30/2024 | LUISANGEL VALENZUELA |
| Corrections Issued | 4/30/2024 | LUISANGEL VALENZUELA |
| Issued | 5/2/2024 | APPLICANT |
| Permit Finaled | 10/8/2025 | JEFFREY HARTLINE |
| CofO in Progress | 10/14/2025 | JEFFREY HARTLINE |
| CofO in Progress | 10/31/2025 | HENRY KIM |
Permit Application Clearance Information
| No Data Available. |
Contact Information
| Contractor | Xterior Innovation Design Build Inc; Lic. No.: 1114844-C53 | , |
| Engineer | Zhang,, Yao; Lic. No.: C74572 | 538 ROCCO CIRCLE CORONA, CA 92882 |
Inspector Information
| JEFFREY HARTLINE, (818) 774-4320 | Office Hours: 7:00-8:00 AM MON-FRI |
| CHRIS CHRISTENSEN, (818) 774-4320 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 6/27/2024 | Partial Approval | JEFFREY HARTLINE |
| Gas Piping or Gas Test | 7/24/2024 | Not Ready for Inspection | JEFFREY HARTLINE |
| Pool Piping | 7/24/2024 | Approved | JEFFREY HARTLINE |
| Rough-Electrical | 7/24/2024 | Not Ready for Inspection | JEFFREY HARTLINE |
| Special/Order Compliance | 7/26/2024 | Corrections Issued | JEFFREY HARTLINE |
| Gas Piping or Gas Test | 7/31/2024 | Approved | JEFFREY HARTLINE |
| Grounding or Bonding | 7/31/2024 | Partial Approval | JEFFREY HARTLINE |
| Excavation/Setback/Form/Re-Bar | 6/23/2025 | Not Ready for Inspection | DAVID SCANTLIN |
| Grounding or Bonding | 6/23/2025 | Approved | DAVID SCANTLIN |
| Pre-Gunite | 7/21/2025 | Corrections Issued | JEFFREY HARTLINE |
| Deputy Shotcrete | 7/22/2025 | Conditional Approval | CHRIS CHRISTENSEN |
| Pre-Gunite | 7/24/2025 | Approved | JEFFREY HARTLINE |
| Deck | 8/15/2025 | Approved | SCOTT SOBEL |
| Grounding or Bonding | 8/15/2025 | Approved | SCOTT SOBEL |
| Enclosure/Fence | 9/12/2025 | Corrections Issued | JEFFREY HARTLINE |
| Enclosure/Fence | 9/16/2025 | Approved | JEFFREY HARTLINE |
| Pre-Gunite | 9/16/2025 | Approved | JEFFREY HARTLINE |
| Final | 10/1/2025 | Corrections Issued | JEFFREY HARTLINE |
| SGSOV-Seismic Gas S/O Valve | 10/1/2025 | SGSOV Not Ready | JEFFREY HARTLINE |
| Final | 10/8/2025 | Permit Finaled | JEFFREY HARTLINE |
| SGSOV-Seismic Gas S/O Valve | 10/8/2025 | SGSOV Approved | JEFFREY HARTLINE |
| Pool Equipment Noise Test | 10/16/2025 | No Access for Inspection | ALFREDO FLORES |
| Pool Equipment Noise Test | 10/22/2025 | Approved | FELIPE PENICHE |