1842 W 51ST ST 90062
Certificate Information: 1842 W 51ST ST 90062
- Application / Permit
- 24016-90000-31221
- Plan Check / Job No.
- --
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over new solid sheathing 13 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone (VHFHSZ). For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council (CRRC). Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0(b)2B. 10 window(s). Window and door change-out (same size & type) for residential buildings. Dual glazing, labeled and certified by National Fenestration Rating Council (NFRC), is required for doors and windows replaced in all residential buildings, three stories or less, per Title 24, Part 6, Section 150.2(b)1B. 2 door(s). Window and door change-out (same size & type) for residential buildings. Dual glazing, labeled and certified by National Fenestration Rating Council (NFRC), is required for doors and windows replaced in all residential buildings, three stories or less, per Title 24, Part 6, Section 150.2(b)1B. Vinyl siding over solid sheathing with an approved water-resistive barrier per valid ICC Evaluation Report # ASTMD3679 on exterior walls at 5 feet or more from property lines for residential buildings. (Applicant to provide a copy of the report to inspector).
- Permit Issued
- Issued on 9/30/2024
- Issuing Office
- Current Status
- Issued on 9/30/2024
Permit Application Status History
| Issued | 9/30/2024 | INTERNET PERMIT |
Permit Application Clearance Information
| No Data Available. |
Contact Information
| Contractor | Owner-Builder | , |
Inspector Information
| SABAS ALONSO, (213) 202-3468 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Floor/Roof Diaphrgm/Shear Wall | 2/27/2025 | Approved | AMY COLIN |
| Interior/Exterior Lathing | 4/3/2025 | No Access for Inspection | AMY COLIN |
| Interior/Exterior Lathing | 4/5/2025 | Corrections Issued | ALEJANDRO DE ARTOLA |
| Interior/Exterior Lathing | 4/7/2025 | Corrections Issued | AMY COLIN |
| Interior/Exterior Lathing | 4/10/2025 | Not Ready for Inspection | AMY COLIN |
| Interior/Exterior Lathing | 4/16/2025 | Approved | AMY COLIN |