629 1/2 N HARPER AVE 90048
Certificate Information: 629 1/2 N HARPER AVE 90048
- Application / Permit
- 24016-30000-11020
- Plan Check / Job No.
- B24WL00694
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- CONVERT (E) GARAGE TO ADU PER LAMC 12.22 A.33 (c)-(d)
- Permit Issued
- Issued on 4/24/2024
- Issuing Office
- West Los Angeles
- Current Status
- CofO Issued on 10/25/2024
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 4/3/2024 | APPLICANT |
| Assigned to Plan Check Engineer | 4/5/2024 | JASON JANGADA |
| Corrections Issued | 4/7/2024 | JASON JANGADA |
| Building Plans Picked Up | 4/8/2024 | APPLICANT |
| Plan Check Approved | 4/24/2024 | ZENA HADDIS |
| Issued | 4/24/2024 | APPLICANT |
| CofO in Progress | 10/11/2024 | JOSE MACIAS |
| Permit Finaled | 10/25/2024 | RUBEN SALAS |
| CofO Issued | 10/25/2024 | RUBEN SALAS |
| Permit Finaled | 10/25/2024 | RUBEN SALAS |
Permit Application Clearance Information
| Address approval | Cleared | 4/12/2024 | ANTHONY TRAN |
| Sewer availability | Cleared | 4/12/2024 | ANTHONY TRAN |
| Eng Process Fee Ord 176,300 | Cleared | 4/15/2024 | ANTHONY TRAN |
Contact Information
| Contractor | Santa Fe Contractors Inc; Lic. No.: 951293-B | 34385 ACTON CANYON RD ACTON, CA 93510 |
| Engineer | Niver,, Kenneth Earl; Lic. No.: S2554 | 10845 LINDBROOK DR STE 203 W LOS ANGELES, CA 90024 |
Inspector Information
| JOSE MACIAS, (213) 202-3125 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 4/30/2024 | Corrections Issued | AMIR NAZARIAN |
| BUILDING-Rough-Frame | 5/20/2024 | Corrections Issued | AMIR NAZARIAN |
| ELECTRICAL-Rough | 5/20/2024 | Corrections Issued | AMIR NAZARIAN |
| Gas Test | 5/20/2024 | Approved | AMIR NAZARIAN |
| Green Building Rough | 5/20/2024 | Not Ready for Inspection | AMIR NAZARIAN |
| Insulation | 5/20/2024 | Corrections Issued | AMIR NAZARIAN |
| METHANE-Rough | 5/20/2024 | Corrections Issued | AMIR NAZARIAN |
| PLUMBING-Rough | 5/20/2024 | Corrections Issued | AMIR NAZARIAN |
| BUILDING-Rough-Frame | 5/29/2024 | Corrections Issued | AMIR NAZARIAN |
| ELECTRICAL-Rough | 5/29/2024 | Corrections Issued | AMIR NAZARIAN |
| Green Building Rough | 5/29/2024 | Not Ready for Inspection | AMIR NAZARIAN |
| METHANE-Final | 5/29/2024 | Approved | AMIR NAZARIAN |
| METHANE-Rough | 5/29/2024 | Approved | AMIR NAZARIAN |
| PLUMBING-Rough | 5/29/2024 | Corrections Issued | AMIR NAZARIAN |
| Deputy Drilled-In Anchors | 6/11/2024 | Conditional Approval | AMIR NAZARIAN |
| ELECTRICAL-Rough | 6/11/2024 | Not Ready for Inspection | AMIR NAZARIAN |
| HVAC-Rough | 6/11/2024 | Not Ready for Inspection | AMIR NAZARIAN |
| Insulation | 6/11/2024 | Not Ready for Inspection | AMIR NAZARIAN |
| PLUMBING-Rough | 6/11/2024 | Not Ready for Inspection | AMIR NAZARIAN |
| BUILDING-Rough-Frame | 6/13/2024 | Corrections Issued | AMIR NAZARIAN |
| ELECTRICAL-Rough | 6/13/2024 | Corrections Issued | AMIR NAZARIAN |
| Green Building Rough | 6/13/2024 | Not Ready for Inspection | AMIR NAZARIAN |
| HVAC-Rough | 6/13/2024 | Corrections Issued | AMIR NAZARIAN |
| Insulation | 6/13/2024 | Partial Approval | AMIR NAZARIAN |
| PLUMBING-Rough | 6/13/2024 | Partial Approval | AMIR NAZARIAN |
| BUILDING-Rough-Frame | 6/24/2024 | Approved | AMIR NAZARIAN |
| Drywall Nailing | 6/24/2024 | Approved | AMIR NAZARIAN |
| ELECTRICAL-Rough | 6/24/2024 | Corrections Issued | AMIR NAZARIAN |
| Green Building Rough | 6/24/2024 | Approved | AMIR NAZARIAN |
| HVAC-Rough | 6/24/2024 | Approved | AMIR NAZARIAN |
| PLUMBING-Rough | 6/24/2024 | Approved | AMIR NAZARIAN |
| Shower Pan | 6/24/2024 | Corrections Issued | AMIR NAZARIAN |
| ELECTRICAL-Rough | 6/26/2024 | Not Ready for Inspection | AMIR NAZARIAN |
| PLUMBING-Rough | 6/26/2024 | Approved | AMIR NAZARIAN |
| Shower Pan | 6/26/2024 | Approved | AMIR NAZARIAN |
| ELECTRICAL-Rough | 7/9/2024 | Approved | AMIR NAZARIAN |
| Interior/Exterior Lathing | 7/9/2024 | Approved | AMIR NAZARIAN |
| ELECTRICAL-Final | 9/3/2024 | Approved | JOSE MACIAS |
| Final | 9/3/2024 | Corrections Issued | JOSE MACIAS |
| Green Building Final | 9/3/2024 | Approved | JOSE MACIAS |
| HVAC-Final | 9/3/2024 | Approved | JOSE MACIAS |
| PLUMBING-Final | 9/3/2024 | Approved | JOSE MACIAS |
| SGSOV-Seismic Gas S/O Valve | 9/3/2024 | SGSOV Approved | JOSE MACIAS |
| Smoke Detectors | 9/3/2024 | Approved | JOSE MACIAS |
| Final | 9/24/2024 | Conditional Approval | JOSE MACIAS |
| Final | 10/8/2024 | OK to Issue CofO | JOSE MACIAS |