7447 W 89TH ST 90045
Certificate Information: 7447 W 89TH ST 90045
- Application / Permit
- 24016-30000-00581
- Plan Check / Job No.
- B24WL00046
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- Reduce (E) Garage Dimesions and Convert into a new Dettached Accessory Dwelling Unit per CA Govt. Code 65852.2(e)(1)(A)
- Permit Issued
- Issued on 5/28/2024
- Issuing Office
- West Los Angeles
- Current Status
- CofO Issued on 12/3/2024
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 1/8/2024 | APPLICANT |
| Assigned to Plan Check Engineer | 1/9/2024 | RICHARD GARCIA |
| Corrections Issued | 1/9/2024 | RICHARD GARCIA |
| Building Plans Picked Up | 1/11/2024 | APPLICANT |
| Applicant returned to address corrections | 3/1/2024 | AMY GUEVARRA |
| Applicant returned to address corrections | 4/4/2024 | EDWIN ESPIN |
| Plan Check Approved | 5/28/2024 | ZENA HADDIS |
| Issued | 5/28/2024 | APPLICANT |
| CofO in Progress | 11/26/2024 | TEMISTOCLES CAAL |
| Permit Finaled | 12/3/2024 | RICHARD STEINBACH |
| CofO Issued | 12/3/2024 | RICHARD STEINBACH |
| Permit Finaled | 12/3/2024 | RICHARD STEINBACH |
Permit Application Clearance Information
| Address approval | Cleared | 1/26/2024 | VLADIMIR ARUTYUNYAN |
| Grading Pre-Inspection | Cleared | 3/4/2024 | VASIL MIHALEV |
| Specific Plan | Cleared | 3/6/2024 | MOHAMMAD HASAN |
| Eng Process Fee Ord 176,300 | Cleared | 3/11/2024 | DARIN LAM |
| Sewer availability | Cleared | 3/11/2024 | DARIN LAM |
| Construction near power lines | Cleared | 5/23/2024 | RIDWAN HARDY |
Contact Information
| Contractor | Jsh Builders Inc; Lic. No.: 1062568-B | 1901 MARSHALLFIELD LN REDONDO BEACH, CA 90278 |
| Engineer | Kang,, Danniel; Lic. No.: S6242 | 1176 N KNOLLWOOD CT ANAHEIM, CA 92801 |
Inspector Information
| MICHAEL LEWIS, (310) 914-3979 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 5/30/2024 | Corrections Issued | HERBERT GIRON |
| Footing/Foundation/Slab | 6/4/2024 | Partial Approval | BOBBY KEY |
| Deputy Drilled-In Anchors | 6/5/2024 | Conditional Approval | BOBBY KEY |
| Deputy Other (see comments) | 6/13/2024 | Approved | BOBBY KEY |
| Footing/Foundation/Slab | 6/13/2024 | Approved | BOBBY KEY |
| HVAC-Rough | 6/13/2024 | Partial Approval | BOBBY KEY |
| Insulation | 6/13/2024 | Partial Approval | BOBBY KEY |
| BUILDING-Rough-Frame | 7/1/2024 | Not Ready for Inspection | BOBBY KEY |
| ELECTRICAL-Rough | 7/1/2024 | Corrections Issued | BOBBY KEY |
| Green Building Rough | 7/1/2024 | Not Ready for Inspection | BOBBY KEY |
| PLUMBING-Rough | 7/1/2024 | Corrections Issued | BOBBY KEY |
| Wood Frame | 7/1/2024 | Partial Approval | BOBBY KEY |
| ELECTRICAL-Rough | 7/12/2024 | Approved | BOBBY KEY |
| Interior/Exterior Lathing | 7/12/2024 | Approved | BOBBY KEY |
| PLUMBING-Rough | 7/12/2024 | Approved | BOBBY KEY |
| BUILDING-Rough-Frame | 7/16/2024 | Approved | BOBBY KEY |
| Green Building Rough | 7/16/2024 | Approved | BOBBY KEY |
| HVAC-Rough | 7/16/2024 | Approved | BOBBY KEY |
| Insulation | 7/22/2024 | Approved | BOBBY KEY |
| Drywall Nailing | 7/26/2024 | Approved | BOBBY KEY |
| Shower Pan | 7/26/2024 | Approved | BOBBY KEY |
| Sewer | 8/5/2024 | Approved | BOBBY KEY |
| Interior/Exterior Lathing | 9/3/2024 | Approved | BOBBY KEY |
| ELECTRICAL-Final | 10/31/2024 | Corrections Issued | TEMISTOCLES CAAL |
| Final | 10/31/2024 | Corrections Issued | TEMISTOCLES CAAL |
| Green Building Final | 10/31/2024 | Corrections Issued | TEMISTOCLES CAAL |
| HVAC-Final | 10/31/2024 | Corrections Issued | TEMISTOCLES CAAL |
| PLUMBING-Final | 10/31/2024 | Approved | TEMISTOCLES CAAL |
| SGSOV-Seismic Gas S/O Valve | 10/31/2024 | SGSOV Approved | TEMISTOCLES CAAL |
| Smoke Detectors | 10/31/2024 | Approved | TEMISTOCLES CAAL |
| ELECTRICAL-Final | 11/15/2024 | Approved | TEMISTOCLES CAAL |
| Final | 11/15/2024 | Corrections Issued | TEMISTOCLES CAAL |
| Green Building Final | 11/15/2024 | Approved | TEMISTOCLES CAAL |
| HVAC-Final | 11/15/2024 | Approved | TEMISTOCLES CAAL |
| Final | 11/26/2024 | OK to Issue CofO | TEMISTOCLES CAAL |