9466 N ROSLYNDALE AVE 91331
Certificate Information: 9466 N ROSLYNDALE AVE 91331
- Application / Permit
- 24016-20000-29282
- Plan Check / Job No.
- B24VN16439
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- Eplan - Convert Existing detached Garage into Accessory Dwelling Unit PER LAMC 12.22 A.33(c) AND (d) . All work per WFPP
- Permit Issued
- Issued on 12/28/2024
- Issuing Office
- Current Status
- CofO Issued on 12/12/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 9/21/2024 | APPLICANT |
| Assigned to Plan Check Engineer | 9/25/2024 | ARAMIK SHAHMIRZAIAN |
| Corrections Issued | 9/26/2024 | ARAMIK SHAHMIRZAIAN |
| Applicant returned to address corrections | 12/12/2024 | ARAMIK SHAHMIRZAIAN |
| Plan Check Approved | 12/23/2024 | ARAMIK SHAHMIRZAIAN |
| Issued | 12/28/2024 | APPLICANT |
| CofO in Progress | 11/24/2025 | DAVID MATSON |
| Permit Finaled | 12/12/2025 | RUBEN SALAS |
| CofO Issued | 12/12/2025 | RUBEN SALAS |
| Permit Finaled | 12/12/2025 | RUBEN SALAS |
Permit Application Clearance Information
| Address approval | Cleared | 9/26/2024 | LEE GUILBEAUX |
| Sewer availability | Cleared | 9/26/2024 | LEE GUILBEAUX |
| Public Works-Highway Ded. | Cleared | 9/26/2024 | LEE GUILBEAUX |
| Eng Process Fee Ord 176,300 | Cleared | 9/30/2024 | LEE GUILBEAUX |
| Construction near power lines | Cleared | 12/9/2024 | RIDWAN HARDY |
| Construction within easement | Cleared | 12/9/2024 | RIDWAN HARDY |
Contact Information
| Contractor | Owner-Builder | , |
Inspector Information
| OGANES TARAKHCHYAN, (818) 374-1162 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| PLUMBING-Rough | 3/4/2025 | Partial Approval | VINCENT HANLEY |
| Sewer | 3/4/2025 | Approved | VINCENT HANLEY |
| Excavation/Setback/Form/Re-Bar | 3/7/2025 | Approved | MATTHEW NELSON |
| Footing/Foundation/Slab | 3/7/2025 | Approved | MATTHEW NELSON |
| BUILDING-Rough-Frame | 5/12/2025 | Corrections Issued | WILLIAM WREN |
| ELECTRICAL-Rough | 5/12/2025 | Corrections Issued | WILLIAM WREN |
| Green Building Rough | 5/12/2025 | Not Ready for Inspection | WILLIAM WREN |
| Insulation | 5/12/2025 | Corrections Issued | WILLIAM WREN |
| ELECTRICAL-Rough | 5/15/2025 | Corrections Issued | VINCENT HANLEY |
| BUILDING-Rough-Frame | 5/27/2025 | Partial Approval | VINCENT HANLEY |
| ELECTRICAL-Rough | 5/27/2025 | Approved | VINCENT HANLEY |
| Green Building Rough | 5/27/2025 | Not Ready for Inspection | VINCENT HANLEY |
| Insulation | 5/27/2025 | Corrections Issued | VINCENT HANLEY |
| PLUMBING-Rough | 5/27/2025 | Approved | VINCENT HANLEY |
| HVAC-Rough | 5/29/2025 | Approved | VINCENT HANLEY |
| Insulation | 5/29/2025 | Approved | VINCENT HANLEY |
| Interior/Exterior Lathing | 5/29/2025 | Partial Approval | VINCENT HANLEY |
| Drywall Nailing | 6/13/2025 | Approved | VINCENT HANLEY |
| ELECTRICAL-Final | 6/13/2025 | Corrections Issued | VINCENT HANLEY |
| Interior/Exterior Lathing | 6/13/2025 | Approved | VINCENT HANLEY |
| Underground Mechanical | 6/13/2025 | Corrections Issued | VINCENT HANLEY |
| BUILDING-Rough-Frame | 9/24/2025 | Approved | VINCENT HANLEY |
| Final | 9/24/2025 | Corrections Issued | VINCENT HANLEY |
| Green Building Final | 9/24/2025 | Approved | VINCENT HANLEY |
| Green Building Rough | 9/24/2025 | Approved | VINCENT HANLEY |
| SGSOV-Seismic Gas S/O Valve | 9/24/2025 | SGSOV Not Ready | VINCENT HANLEY |
| Service/Power Release | 9/24/2025 | Corrections Issued | VINCENT HANLEY |
| Smoke Detectors | 9/24/2025 | Approved | VINCENT HANLEY |
| ELECTRICAL-Final | 11/3/2025 | Approved | VINCENT HANLEY |
| Final | 11/3/2025 | OK to Issue CofO | VINCENT HANLEY |
| HVAC-Final | 11/3/2025 | Approved | VINCENT HANLEY |
| PLUMBING-Final | 11/3/2025 | Approved | VINCENT HANLEY |
| SGSOV-Seismic Gas S/O Valve | 11/3/2025 | SGSOV Not Required | VINCENT HANLEY |
| Service/Power Release | 11/3/2025 | Approved | VINCENT HANLEY |