6550 N BELLAIRE AVE 91606
Certificate Information: 6550 N BELLAIRE AVE 91606
- Application / Permit
- 24016-20000-27127
- Plan Check / Job No.
- B24VN14305
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- 7'-0" X 15'-8" ADDITION TO AND CONVERT EXISTING DETACHED GARAGE INTO ACCESSORY DWELLING UNIT PER LAMC 12.22 A.33(c) AND (d)
- Permit Issued
- Issued on 10/14/2024
- Issuing Office
- Current Status
- CofO Issued on 2/19/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 8/23/2024 | APPLICANT |
| Assigned to Plan Check Engineer | 8/28/2024 | DANIEL ABRAMYAN |
| Corrections Issued | 8/29/2024 | DANIEL ABRAMYAN |
| Plan Check Approved | 9/12/2024 | OMAR GARNICA |
| Issued | 10/14/2024 | APPLICANT |
| CofO in Progress | 2/14/2025 | GAREN HAYRAPETYAN |
| Permit Finaled | 2/19/2025 | RUBEN SALAS |
| CofO Issued | 2/19/2025 | RUBEN SALAS |
| Permit Finaled | 2/19/2025 | RUBEN SALAS |
Permit Application Clearance Information
| Address approval | Cleared | 8/29/2024 | EDGAR ALCARAZ |
| Eng Process Fee Ord 176,300 | Cleared | 8/29/2024 | EDGAR ALCARAZ |
| Roof/Waste drainage to street | Cleared | 8/29/2024 | EDGAR ALCARAZ |
| Sewer availability | Cleared | 8/29/2024 | EDGAR ALCARAZ |
| Construction near power lines | Cleared | 9/5/2024 | WALTER RAMIREZ |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Tangonan,, Jeffrey Tolentino; Lic. No.: C83522 | 17770 CAPE JASMINE RD CANYON COUNTRY, CA 91387 |
Inspector Information
| WAYNE REGESTER, (818) 374-1164 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 12/4/2024 | Corrections Issued | GAREN HAYRAPETYAN |
| PLUMBING-Rough | 12/4/2024 | Not Ready for Inspection | GAREN HAYRAPETYAN |
| Underground Mechanical | 12/4/2024 | Not Ready for Inspection | GAREN HAYRAPETYAN |
| Excavation/Setback/Form/Re-Bar | 12/10/2024 | Approved | GAREN HAYRAPETYAN |
| Footing/Foundation/Slab | 12/10/2024 | Approved | GAREN HAYRAPETYAN |
| PLUMBING-Rough | 12/10/2024 | Partial Approval | GAREN HAYRAPETYAN |
| Sewer | 12/10/2024 | Partial Approval | GAREN HAYRAPETYAN |
| BUILDING-Rough-Frame | 12/24/2024 | Not Ready for Inspection | OGANES TARAKHCHYAN |
| ELECTRICAL-Rough | 12/24/2024 | Not Ready for Inspection | OGANES TARAKHCHYAN |
| Green Building Rough | 12/24/2024 | Not Ready for Inspection | OGANES TARAKHCHYAN |
| PLUMBING-Rough | 12/24/2024 | Partial Approval | OGANES TARAKHCHYAN |
| BUILDING-Rough-Frame | 1/2/2025 | Partial Approval | OGANES TARAKHCHYAN |
| ELECTRICAL-Rough | 1/2/2025 | Not Ready for Inspection | OGANES TARAKHCHYAN |
| Green Building Rough | 1/2/2025 | Approved | OGANES TARAKHCHYAN |
| Rough-Elec/Plmb/HVAC | 1/2/2025 | Partial Approval | OGANES TARAKHCHYAN |
| Insulation | 1/8/2025 | Approved | MICHAEL CORTEZ |
| Interior/Exterior Lathing | 1/8/2025 | Corrections Issued | MICHAEL CORTEZ |
| Interior/Exterior Lathing | 1/10/2025 | Approved | GAREN HAYRAPETYAN |
| Drywall Nailing | 1/15/2025 | Approved | OGANES TARAKHCHYAN |
| BUILDING-Rough-Frame | 2/6/2025 | Approved | GAREN HAYRAPETYAN |
| Final | 2/6/2025 | Corrections Issued | GAREN HAYRAPETYAN |
| Green Building Final | 2/6/2025 | Not Ready for Inspection | GAREN HAYRAPETYAN |
| SGSOV-Seismic Gas S/O Valve | 2/6/2025 | SGSOV Approved | GAREN HAYRAPETYAN |
| Smoke Detectors | 2/6/2025 | Approved | GAREN HAYRAPETYAN |
| Final | 2/11/2025 | Not Ready for Inspection | OGANES TARAKHCHYAN |
| Green Building Final | 2/11/2025 | Not Ready for Inspection | OGANES TARAKHCHYAN |
| Final | 2/14/2025 | OK to Issue CofO | GAREN HAYRAPETYAN |
| Green Building Final | 2/14/2025 | Approved | GAREN HAYRAPETYAN |