6157 N SYLVIA AVE 91335
Certificate Information: 6157 N SYLVIA AVE 91335
- Application / Permit
- 24016-20000-27027
- Plan Check / Job No.
- B24VN14145
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- Eplan Convert and addition 10'-10" x 20' existing garage to Accessory Dwelling Unit PER LAMC 12.22 A.33(c) AND (d). All work per engineering
- Permit Issued
- Issued on 12/10/2024
- Issuing Office
- Current Status
- Issued on 12/10/2024
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 8/22/2024 | APPLICANT |
| Assigned to Plan Check Engineer | 8/27/2024 | JOHN MESIAS |
| Corrections Issued | 8/28/2024 | JOHN MESIAS |
| Applicant returned to address corrections | 10/23/2024 | LAWRENCE QUIRANTE |
| Applicant returned to address corrections | 11/13/2024 | LAWRENCE QUIRANTE |
| Applicant returned to address corrections | 11/27/2024 | ARAMIK SHAHMIRZAIAN |
| Plan Check Approved | 12/10/2024 | ARAMIK SHAHMIRZAIAN |
| Issued | 12/10/2024 | APPLICANT |
| CofO in Progress | 9/3/2025 | MORRIS JACKSON |
| CofO Issued-Status Void | 10/27/2025 | JOHN JANSON |
| Permit Finaled-Status Void | 10/27/2025 | JOHN JANSON |
| Re-Activate Permit | 10/28/2025 | JOHN JANSON |
Permit Application Clearance Information
| Address approval | Cleared | 10/8/2024 | BIAINA HARITUNIAN |
| Eng Process Fee Ord 176,300 | Cleared | 10/8/2024 | BIAINA HARITUNIAN |
| Roof/Waste drainage to street | Cleared | 10/8/2024 | BIAINA HARITUNIAN |
| Sewer availability | Cleared | 10/8/2024 | BIAINA HARITUNIAN |
| ZI | Cleared | 10/22/2024 | BRENNEN OBETO |
| Construction near power lines | Cleared | 12/4/2024 | TINA MIRANDA |
Contact Information
| Contractor | Bellagio Design Build Corporation; Lic. No.: 935571-B | , |
| Engineer | Rhee,, Kyle; Lic. No.: NA78215 | , |
Inspector Information
| JON MCHUGH, (818) 774-4348 | Office Hours: 7:00-8:00 AM MON-FRI |
| IVAN SARABIA, (818) 774-4348 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 12/24/2024 | Approved | JOHN COLEMAN |
| Deputy Drilled-In Anchors | 1/10/2025 | Conditional Approval | JON MCHUGH |
| Sewer | 1/14/2025 | Not Ready for Inspection | MORRIS JACKSON |
| Underground Mechanical | 1/14/2025 | Partial Approval | MORRIS JACKSON |
| Footing/Foundation/Slab | 1/23/2025 | Approved | MORRIS JACKSON |
| Floor/Roof Diaphrgm/Shear Wall | 2/20/2025 | Partial Approval | MORRIS JACKSON |
| ELECTRICAL-Rough | 3/5/2025 | Approved | MORRIS JACKSON |
| Floor/Roof Diaphrgm/Shear Wall | 3/5/2025 | Partial Approval | MORRIS JACKSON |
| Green Building Rough | 3/5/2025 | Not Ready for Inspection | MORRIS JACKSON |
| PLUMBING-Rough | 3/5/2025 | Approved | MORRIS JACKSON |
| Underground Mechanical | 3/5/2025 | Approved | MORRIS JACKSON |
| HVAC-Rough | 3/10/2025 | Approved | MORRIS JACKSON |
| Sewer | 3/10/2025 | Approved | MORRIS JACKSON |
| BUILDING-Rough-Frame | 3/28/2025 | Not Ready for Inspection | MORRIS JACKSON |
| Final | 3/28/2025 | Not Ready for Inspection | MORRIS JACKSON |
| Green Building Final | 3/28/2025 | Not Ready for Inspection | MORRIS JACKSON |
| Green Building Rough | 3/28/2025 | Not Ready for Inspection | MORRIS JACKSON |
| SGSOV-Seismic Gas S/O Valve | 3/28/2025 | SGSOV Not Ready | MORRIS JACKSON |
| Smoke Detectors | 3/28/2025 | Not Ready for Inspection | MORRIS JACKSON |
| Interior/Exterior Lathing | 4/1/2025 | Not Ready for Inspection | MORRIS JACKSON |
| BUILDING-Rough-Frame | 4/9/2025 | Approved | ROBERT GOLD |
| Green Building Rough | 4/9/2025 | Approved | ROBERT GOLD |
| Interior/Exterior Lathing | 4/9/2025 | Approved | ROBERT GOLD |
| Insulation | 4/16/2025 | Approved | MORRIS JACKSON |
| Interior/Exterior Lathing | 4/16/2025 | Partial Approval | MORRIS JACKSON |
| Drywall Nailing | 4/23/2025 | Approved | MORRIS JACKSON |
| Interior/Exterior Lathing | 4/23/2025 | Approved | MORRIS JACKSON |
| Final | 7/23/2025 | Corrections Issued | MORRIS JACKSON |
| Green Building Final | 7/23/2025 | Approved | MORRIS JACKSON |
| SGSOV-Seismic Gas S/O Valve | 7/23/2025 | SGSOV Approved | MORRIS JACKSON |
| Smoke Detectors | 7/23/2025 | Approved | MORRIS JACKSON |
| Final | 8/14/2025 | Not Ready for Inspection | JON MCHUGH |
| Final | 8/22/2025 | OK to Issue CofO | MORRIS JACKSON |
| Service/Power Release | 8/22/2025 | Approved | MORRIS JACKSON |