17230 W SUNBURST ST 91325
Certificate Information: 17230 W SUNBURST ST 91325
- Application / Permit
- 24016-20000-18893
- Plan Check / Job No.
- B24VN08091
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- NEW 32.50' X 8.58' PATIO COVER ADDITION TO THE (E) SINGLE FAMILY DWELLING. TO REPLACE DOOR, INSULATION, INTERIOR WALL, CEILING FINISHES, ROOF FRAMING, EXTERIOR STUCCO PLASTER, TILE ROOFING IN THE (E) SINGLE FAMILY DWELLING.
- Permit Issued
- Issued on 7/22/2024
- Issuing Office
- Current Status
- CofO Issued on 5/15/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 6/7/2024 | APPLICANT |
| Assigned to Plan Check Engineer | 6/12/2024 | GIOVANNY CHAVEZ |
| Corrections Issued | 6/13/2024 | GIOVANNY CHAVEZ |
| Applicant returned to address corrections | 7/9/2024 | GIOVANNY CHAVEZ |
| Plan Check Approved | 7/19/2024 | ALEC MOUSAKHANIAN |
| Issued | 7/22/2024 | APPLICANT |
| CofO in Progress | 5/12/2025 | CHRISTOPHER ROJAS |
| Permit Finaled | 5/15/2025 | RUBEN SALAS |
| CofO Issued | 5/15/2025 | RUBEN SALAS |
| Permit Finaled | 5/15/2025 | RUBEN SALAS |
Permit Application Clearance Information
| Roof/Waste drainage to street | Cleared | 7/12/2024 | BRYAN GODINEZ |
| Eng Process Fee Ord 176,300 | Cleared | 7/16/2024 | BRYAN GODINEZ |
Contact Information
| Contractor | H & H Builders And Restoration Inc; Lic. No.: 743872-B | , |
| Contractor | H & H Restoration; Lic. No.: 743872-B | , |
| Engineer | Mellor,, Ian; Lic. No.: S5367 | 4109 CONRAD DR SPRING VALLEY, CA 91977 |
Inspector Information
| CHRISTOPHER ROJAS, (818) 374-1160 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 8/20/2024 | Corrections Issued | JAVIER RAMOS JR |
| Floor/Roof Diaphrgm/Shear Wall | 9/13/2024 | Partial Approval | JAVIER RAMOS JR |
| Footing/Foundation/Slab | 9/13/2024 | Approved | JAVIER RAMOS JR |
| BUILDING-Rough-Frame | 11/21/2024 | Partial Approval | JAVIER RAMOS JR |
| ELECTRICAL-Rough | 11/21/2024 | Approved | JAVIER RAMOS JR |
| Drywall Nailing | 1/28/2025 | Approved | LOUIS ESCOTO |
| Insulation | 1/28/2025 | Approved | LOUIS ESCOTO |
| Interior/Exterior Lathing | 1/28/2025 | Approved | LOUIS ESCOTO |
| Order to Comply | 1/28/2025 | OTC Issued | LOUIS ESCOTO |
| BUILDING-Rough-Frame | 4/29/2025 | Approved | CHRISTOPHER ROJAS |
| Final | 4/29/2025 | Corrections Issued | CHRISTOPHER ROJAS |
| Green Building Final | 4/29/2025 | Not Ready for Inspection | CHRISTOPHER ROJAS |
| Green Building Rough | 4/29/2025 | Approved | CHRISTOPHER ROJAS |
| SGSOV-Seismic Gas S/O Valve | 4/29/2025 | SGSOV Approved | CHRISTOPHER ROJAS |
| Smoke Detectors | 4/29/2025 | Approved | CHRISTOPHER ROJAS |
| Final | 5/8/2025 | OK to Issue CofO | CHRISTOPHER ROJAS |
| Green Building Final | 5/8/2025 | Approved | CHRISTOPHER ROJAS |