4606 W ADAMS BLVD 90016
Certificate Information: 4606 W ADAMS BLVD 90016
- Application / Permit
- 24016-10000-30778
- Plan Check / Job No.
- B24LA24539
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Commercial
- Primary Use
- (8) Auto Repair Garage
- Work Description
- ePlan. Repair and reinforcement of four (4) existing timber roof trusses. Remove existing west facing 13" URM wall, and replace with new 8" CMU wall. Remove and replace rotted roof framing members and sheathing as required. Add new accessible toilet room.
- Permit Issued
- Issued on 2/26/2025
- Issuing Office
- Current Status
- Issued on 2/26/2025
Permit Application Status History
| Submitted | 9/26/2024 | APPLICANT |
| Assigned to Plan Check Engineer | 10/3/2024 | KESETE HAREGOT |
| Assigned to Zoning Architect | 10/3/2024 | FRANCIS AHN |
| Corrections Issued | 10/8/2024 | KESETE HAREGOT |
| Quality Review Completed | 10/9/2024 | RODOLFO ARIAS |
| Applicant returned to address corrections | 10/23/2024 | KESETE HAREGOT |
| Applicant returned to address corrections | 1/27/2025 | KESETE HAREGOT |
| Plan Check Approved | 2/20/2025 | KESETE HAREGOT |
| Issued | 2/26/2025 | APPLICANT |
Permit Application Clearance Information
| Historic Resource Verification | Cleared | 1/24/2025 | RAFAEL FONTES |
| Green Code | Cleared | 1/25/2025 | Fernando Flores |
| Community Plan Implem. Overlay | Cleared | 2/11/2025 | ISAIAH ROSS |
| Redevelopment Project Area | Cleared | 2/12/2025 | YASMINE BASHIRI |
| DAS Clearance | Cleared | 2/18/2025 | Fernando Flores |
| Zoning Plan Check | Cleared | 2/19/2025 | Fernando Flores |
Contact Information
| Contractor | S & T Contractors Service Inc; Lic. No.: 950263-B | 21163 CENTRE POINTE PARKWAY SANTA CLARITA, CA 91350 |
| Engineer | Robson,, Honor Michelle; Lic. No.: NA62694 | , |
Inspector Information
| IAN BLINN, (213) 482-7361 | Office Hours: 7:00-8:00 AM MON-FRI |
| CHRISTOPHER BLACKWOOD, (213) 482-7361 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 3/4/2025 | Approved | MARTIN TAVITIAN |
| Pre-Inspection | 3/5/2025 | Corrections Issued | MARTIN TAVITIAN |
| Pre-Inspection | 3/11/2025 | Corrections Issued | MARTIN TAVITIAN |
| Special/Order Compliance | 3/12/2025 | Partial Inspection | MARTIN TAVITIAN |
| Order to Comply | 3/14/2025 | Approved | MARTIN TAVITIAN |
| Masonry Wall/Backfill | 7/2/2025 | Partial Approval | RONALD JIMENEZ |
| Masonry Wall/Backfill | 7/7/2025 | Partial Approval | MARTIN TAVITIAN |
| Deputy Reinf. Masonry | 7/9/2025 | Partial Approval | MARTIN TAVITIAN |
| Masonry Wall/Backfill | 7/9/2025 | Approved | MARTIN TAVITIAN |
| Footing/Foundation/Slab | 7/22/2025 | Partial Approval | MARTIN TAVITIAN |
| Wood Frame | 7/29/2025 | Not Ready for Inspection | MARTIN TAVITIAN |
| Wood Frame | 7/30/2025 | Partial Approval | PAUL BAZERKANIAN |
| Floor/Roof Diaphrgm/Shear Wall | 7/31/2025 | Partial Approval | ALFREDO LOPEZ |
| Wood Frame | 9/24/2025 | Partial Approval | MARTIN TAVITIAN |
| Drywall Nailing | 11/3/2025 | Partial Approval | MARTIN TAVITIAN |
| Drywall Nailing | 11/4/2025 | Not Ready for Inspection | CHRISTOPHER BLACKWOOD |
| Final | 12/22/2025 | Not Ready for Inspection | MARTIN TAVITIAN |
| Green Building Final | 12/22/2025 | Approved | MARTIN TAVITIAN |
| MERV13>=Final | 12/22/2025 | Not Ready for Inspection | MARTIN TAVITIAN |
| SGSOV-Seismic Gas S/O Valve | 12/22/2025 | SGSOV Not Ready | MARTIN TAVITIAN |
| Smoke Detectors | 12/22/2025 | Not Ready for Inspection | MARTIN TAVITIAN |