1218 1/2 S SYCAMORE AVE 90019
Certificate Information: 1218 1/2 S SYCAMORE AVE 90019
- Application / Permit
- 24016-10000-25169
- Plan Check / Job No.
- B24LA16957
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- CONVERT (E) TWO-CAR GARAGE & RECREATION ROOM TO (N) DETACHED ADU. WORK PER WFPP.
- Permit Issued
- Issued on 4/22/2025
- Issuing Office
- Metro
- Current Status
- CofO Issued on 2/26/2026
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 8/7/2024 | APPLICANT |
| Assigned to Plan Check Engineer | 8/8/2024 | NEHEMIAS RAMOS |
| Corrections Issued | 8/10/2024 | NEHEMIAS RAMOS |
| Building Plans Picked Up | 8/15/2024 | APPLICANT |
| Applicant returned to address corrections | 8/27/2024 | ADAM HEGAZI |
| Applicant returned to address corrections | 10/11/2024 | JOHN MESIAS |
| Plan Check Approved | 4/22/2025 | JOHN MESIAS |
| Issued | 4/22/2025 | APPLICANT |
| CofO in Progress | 2/24/2026 | JUSTIN HAWLEY |
| Permit Finaled | 2/26/2026 | DEROLD HAUFF |
| CofO Issued | 2/26/2026 | DEROLD HAUFF |
| Permit Finaled | 2/26/2026 | DEROLD HAUFF |
Permit Application Clearance Information
| Construction near power lines | Cleared | 11/19/2024 | RIDWAN HARDY |
| Address approval | Cleared | 2/18/2025 | CARLOS RAMIREZ |
| Sewer availability | Cleared | 2/18/2025 | CARLOS RAMIREZ |
| Eng Process Fee Ord 176,300 | Cleared | 2/26/2025 | CARLOS RAMIREZ |
| HPOZ | Cleared | 4/8/2025 | ERIK VAN BREENE |
Contact Information
| Contractor | Owner-Builder | , |
Inspector Information
| JUSTIN HAWLEY, (213) 202-3432 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 8/21/2025 | Partial Inspection | ARTHUR NEGRETE |
| Green Building Rough | 8/21/2025 | Not Ready for Inspection | ARTHUR NEGRETE |
| METHANE-Rough | 8/21/2025 | Not Ready for Inspection | ARTHUR NEGRETE |
| Deputy Drilled-In Anchors | 9/10/2025 | Conditional Approval | JUSTIN HAWLEY |
| Footing/Foundation/Slab | 9/12/2025 | Approved | JUSTIN HAWLEY |
| Green Building Rough | 9/12/2025 | Not Ready for Inspection | JUSTIN HAWLEY |
| Insulation | 9/16/2025 | Corrections Issued | ALEX COLIN |
| Deputy Wood Construction | 9/17/2025 | Conditional Approval | ALEX COLIN |
| Insulation | 9/18/2025 | Corrections Issued | BRENDAN MORELLI |
| Pre-Inspection | 9/23/2025 | Corrections Issued | JUSTIN HAWLEY |
| Green Building Rough | 10/15/2025 | Not Ready for Inspection | JUSTIN HAWLEY |
| Pre-Inspection | 10/15/2025 | Approved | JUSTIN HAWLEY |
| Insulation | 10/23/2025 | Corrections Issued | DEVON JACKSON |
| Insulation | 10/31/2025 | Approved | JUSTIN HAWLEY |
| Drywall Nailing | 11/6/2025 | Approved | DEVON JACKSON |
| Insulation | 11/6/2025 | Approved | DEVON JACKSON |
| Interior/Exterior Lathing | 11/6/2025 | Partial Approval | DEVON JACKSON |
| Final | 12/12/2025 | Corrections Issued | JUSTIN HAWLEY |
| Green Building Final | 12/12/2025 | Not Ready for Inspection | JUSTIN HAWLEY |
| Green Building Rough | 12/12/2025 | Approved | JUSTIN HAWLEY |
| SGSOV-Seismic Gas S/O Valve | 12/12/2025 | SGSOV Approved | JUSTIN HAWLEY |
| Smoke Detectors | 12/12/2025 | Not Ready for Inspection | JUSTIN HAWLEY |
| Special/Order Compliance | 12/12/2025 | Corrections Issued | JUSTIN HAWLEY |
| Wood Frame | 12/12/2025 | Approved | JUSTIN HAWLEY |
| Final | 1/26/2026 | Corrections Issued | WILLIAM SIERRA |
| Green Building Final | 1/26/2026 | Not Ready for Inspection | WILLIAM SIERRA |
| Smoke Detectors | 1/26/2026 | Not Ready for Inspection | WILLIAM SIERRA |
| Final | 2/24/2026 | OK to Issue CofO | JUSTIN HAWLEY |
| Green Building Final | 2/24/2026 | Approved | JUSTIN HAWLEY |
| Smoke Detectors | 2/24/2026 | Approved | JUSTIN HAWLEY |