5347-5349 W THORNBURN ST 90045
Certificate Information: 5347-5349 W THORNBURN ST 90045
- Application / Permit
- 24016-10000-21060
- Plan Check / Job No.
- B24LA12498
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- eplan: Convert existing attached garage into a Junior Accessory Dwelling Unit (JADU) in existing single family dewlling per engineer calc (Junior ADU per State Law, CA Govt. Code 65852.2(e)(1)(A) and 65852.22)
- Permit Issued
- Issued on 1/10/2025
- Issuing Office
- Current Status
- Issued on 1/10/2025
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 7/2/2024 | APPLICANT |
| Assigned to Plan Check Engineer | 7/8/2024 | AUNG SOE |
| Corrections Issued | 7/10/2024 | AUNG SOE |
| Applicant returned to address corrections | 1/9/2025 | AUNG SOE |
| Plan Check Approved | 1/9/2025 | AUNG SOE |
| Issued | 1/10/2025 | APPLICANT |
Permit Application Clearance Information
| Address approval | Cleared | 7/15/2024 | BRENDEN HAWK |
| Sewer availability | Cleared | 7/15/2024 | BRENDEN HAWK |
| Eng Process Fee Ord 176,300 | Cleared | 7/22/2024 | BRENDEN HAWK |
| Specific Plan | Cleared | 8/15/2024 | PEDRO AYALA |
| Construction near power lines | Cleared | 10/31/2024 | TINA MIRANDA |
| Construction within easement | Cleared | 10/31/2024 | TINA MIRANDA |
| Grading Pre-Inspection | Cleared | 1/9/2025 | AUNG SOE |
Contact Information
| Architect | Dembsky,, Amit; Lic. No.: C30383 | 5739 KANAN ROAD # 133 AGOURA HILLS, CA 91301 |
| Architect | Dembsky,, Amit; Lic. No.: NA30383 | , |
| Contractor | Preferred Home Builders Inc; Lic. No.: 773147-B | , |
Inspector Information
| MICHAEL LEWIS, (310) 914-3979 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| BUILDING-Rough-Frame | 7/2/2025 | Corrections Issued | RUBEN RIVAS |
| ELECTRICAL-Rough | 7/2/2025 | Corrections Issued | RUBEN RIVAS |
| HVAC-Rough | 7/2/2025 | Approved | RUBEN RIVAS |
| MERV13>=Rough | 7/2/2025 | Not Ready for Inspection | RUBEN RIVAS |
| PLUMBING-Rough | 7/2/2025 | Corrections Issued | RUBEN RIVAS |
| ELECTRICAL-Rough | 7/3/2025 | Approved | RUBEN RIVAS |
| PLUMBING-Rough | 7/3/2025 | Approved | RUBEN RIVAS |
| Insulation | 7/9/2025 | Not Ready for Inspection | ANTHONY EGSON |
| Interior/Exterior Lathing | 7/9/2025 | Not Ready for Inspection | ANTHONY EGSON |
| Shower Pan | 7/9/2025 | Not Ready for Inspection | ANTHONY EGSON |