8701 S BELLANCA AVE 90045
Certificate Information: 8701 S BELLANCA AVE 90045
- Application / Permit
- 24016-10000-13264
- Plan Check / Job No.
- B24LA07338
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Commercial
- Primary Use
- (22) Warehouse
- Work Description
- CHANGE OF USE FOR A PORTION OF THE EXISTING OFFICES (B OCCUPANCY) ON THE FIRST FLOOR, RESTORE TO PREVIOUS WAREHOUSE (S OCCUPANCY) USE. EXISTING BUILDING CORE AND SHELL TO REMAIN. TENANT IMPROVEMENT WORK ONLY ON FIRST AND SECOND FLOORS. DEMOLITION OF INTERIOR PARTITIONS, CEILINGS, REPLACE LIGHT FIXTURES ('LIKE FOR LIKE'). EXISTING PLUMBING FIXTURES TO REMAIN AS IS. NEW FLOOR FINISHES, PAINT WALLS AND GYP. BD. CEILINGS. MEP UNDER SEPARATE PERMIT.
- Permit Issued
- Issued on 9/19/2024
- Issuing Office
- Current Status
- CofO Issued on 3/4/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 4/22/2024 | APPLICANT |
| Assigned to Zoning Architect | 5/2/2024 | ERIC ROMERO |
| Assigned to Plan Check Engineer | 5/2/2024 | JOE VO |
| Corrections Issued | 5/9/2024 | JOE VO |
| Quality Review Completed | 5/10/2024 | PRANITA SHAH |
| Applicant returned to address corrections | 6/27/2024 | JOE VO |
| Plan Check Approved | 9/3/2024 | JOE VO |
| Issued | 9/19/2024 | APPLICANT |
| CofO in Progress | 3/3/2025 | RICARDO ROBLES |
| Permit Finaled | 3/4/2025 | DAVID TSAU |
| CofO Issued | 3/4/2025 | DAVID TSAU |
| Permit Finaled | 3/4/2025 | DAVID TSAU |
Permit Application Clearance Information
| Sewer availability | Cleared | 5/31/2024 | VLADIMIR ARUTYUNYAN |
| Eng Process Fee Ord 176,300 | Cleared | 6/3/2024 | DARIN LAM |
| Green Code | Cleared | 7/2/2024 | Ricardo Ramirez Solis |
| DAS Clearance | Cleared | 7/17/2024 | Ricardo Ramirez Solis |
| Specific Plan | Cleared | 8/28/2024 | FREDDY GARCIA |
| Zoning Plan Check | Cleared | 8/28/2024 | ERIC ROMERO |
Contact Information
| Architect | Algaze,, Nelson; Lic. No.: C21090 | 1524 1ST STREET MANHATTAN BEACH, CA 90266 |
| Contractor | E-Builders Group Inc; Lic. No.: 1027707-B | , |
Inspector Information
| DANIEL ARMENTA, (310) 914-3925 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Light Gage Steel Frame | 10/17/2024 | Not Ready for Inspection | GRANT WOODS |
| T-Bar Ceiling | 11/18/2024 | Not Ready for Inspection | GRANT WOODS |
| T-Bar Ceiling | 12/10/2024 | Not Ready for Inspection | GRANT WOODS |
| T-Bar Ceiling | 1/22/2025 | Approved | JOEY BUCHANAN |
| Final | 1/31/2025 | OK to Issue CofO | RICARDO ROBLES |
| Green Building Final | 1/31/2025 | Approved | RICARDO ROBLES |
| Green Building Rough | 1/31/2025 | Approved | RICARDO ROBLES |
| Reinforced Masonry Frame | 1/31/2025 | Approved | RICARDO ROBLES |
| SGSOV-Seismic Gas S/O Valve | 1/31/2025 | SGSOV Approved | RICARDO ROBLES |
| Smoke Detectors | 1/31/2025 | Approved | RICARDO ROBLES |