3561 1/2 S COCHRAN AVE 90016

Certificate Information: 3561 1/2 S COCHRAN AVE 90016

Application / Permit
24016-10000-11921
Plan Check / Job No.
B24LA06544
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
E-plan. Convert existing detached garage into an ADU and 1-story addition
Permit Issued
Issued on 7/17/2024
Issuing Office
Current Status
CofO Issued on 2/14/2025
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 4/11/2024 APPLICANT
Assigned to Plan Check Engineer 4/16/2024 DANIEL SANJUAN
Corrections Issued 4/17/2024 DANIEL SANJUAN
Applicant returned to address corrections 7/4/2024 KELVIN CHUONG
Plan Check Approved 7/17/2024 DANIEL SANJUAN
Issued 7/17/2024 APPLICANT
CofO in Progress 1/16/2025 ARTHUR NEGRETE
Permit Finaled 2/14/2025 DEROLD HAUFF
CofO Issued 2/14/2025 DEROLD HAUFF
Permit Finaled 2/14/2025 DEROLD HAUFF

Permit Application Clearance Information

Address approval Cleared 5/17/2024 CELINA MORENO
Roof/Waste drainage to street Cleared 5/17/2024 CELINA MORENO
Eng Process Fee Ord 176,300 Cleared 5/21/2024 CELINA MORENO
Sewer availability Cleared 5/21/2024 CELINA MORENO
Construction near power lines Cleared 6/26/2024 RIDWAN HARDY
Construction within easement Cleared 6/26/2024 RIDWAN HARDY

Contact Information

Contractor Owner-Builder       ,
Engineer Christenson,, Paul Scott; Lic. No.: NA57182       ,

Inspector Information

DAVID WILLIAMS, (213) 202-3126 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 7/19/2024 Approved ARTHUR NEGRETE
Underground Mechanical 8/5/2024 Approved JUSTIN HAWLEY
Deputy Wood Construction 8/12/2024 Approved ARTHUR NEGRETE
Deputy Drilled-In Anchors 8/13/2024 Approved ARTHUR NEGRETE
Footing/Foundation/Slab 8/19/2024 Approved ARTHUR NEGRETE
METHANE-Barrier 8/19/2024 Approved ARTHUR NEGRETE
METHANE-Subgrade 8/19/2024 Approved ARTHUR NEGRETE
ELECTRICAL-Rough 9/20/2024 Not Ready for Inspection RONNIE MINDANAO
Gas Test 9/20/2024 Partial Approval RONNIE MINDANAO
BUILDING-Rough-Frame 9/24/2024 Partial Approval ARTHUR NEGRETE
ELECTRICAL-Rough 9/24/2024 Approved ARTHUR NEGRETE
Green Building Rough 9/24/2024 Not Ready for Inspection ARTHUR NEGRETE
METHANE-Rough 9/24/2024 Approved ARTHUR NEGRETE
PLUMBING-Rough 9/24/2024 Approved ARTHUR NEGRETE
Floor/Roof Diaphrgm/Shear Wall 9/26/2024 Approved ARTHUR NEGRETE
Green Building Final 9/26/2024 Not Ready for Inspection ARTHUR NEGRETE
HVAC-Rough 9/26/2024 Approved ARTHUR NEGRETE
Green Building Rough 10/15/2024 Approved NICHOLAS LOPEZ
Insulation 10/15/2024 Approved NICHOLAS LOPEZ
Interior/Exterior Lathing 10/15/2024 Partial Approval NICHOLAS LOPEZ
Drywall Nailing 10/18/2024 Approved NICHOLAS LOPEZ
BUILDING-Rough-Frame 11/22/2024 Approved ARTHUR NEGRETE
Final 11/22/2024 Not Ready for Inspection ARTHUR NEGRETE
Green Building Final 11/22/2024 Not Ready for Inspection ARTHUR NEGRETE
SGSOV-Seismic Gas S/O Valve 11/22/2024 SGSOV Approved ARTHUR NEGRETE
Smoke Detectors 11/22/2024 Corrections Issued ARTHUR NEGRETE
ELECTRICAL-Final 11/26/2024 Corrections Issued JOAQUIN GREENOUGH
HVAC-Final 11/26/2024 Corrections Issued JOAQUIN GREENOUGH
PLUMBING-Final 11/26/2024 Approved JOAQUIN GREENOUGH
Pre-Inspection 11/26/2024 Not Ready for Inspection JOAQUIN GREENOUGH
Green Building Final 12/6/2024 Approved JOSE MACIAS
HVAC-Final 12/6/2024 Approved JOSE MACIAS
Smoke Detectors 12/6/2024 Approved JOSE MACIAS
ELECTRICAL-Final 12/13/2024 Corrections Issued ARTHUR NEGRETE
Final 12/13/2024 Not Ready for Inspection ARTHUR NEGRETE
ELECTRICAL-Final 12/17/2024 Approved ARTHUR NEGRETE
Final 12/17/2024 Partial Approval ARTHUR NEGRETE
Final 1/15/2025 OK to Issue CofO ARTHUR NEGRETE