12721 W CASWELL AVE 90066

Certificate Information: 12721 W CASWELL AVE 90066

Application / Permit
24016-10000-09721
Plan Check / Job No.
B24LA05169
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Apartment
Primary Use
(5) Apartment
Work Description
SOFT STORY RETROFIT PER LAMC DIV 93, INSTALL (2) SPECIAL CANTILEVER STEEL COLUMN SYSTEM & GRADE BEAM
Permit Issued
Issued on 11/21/2024
Issuing Office
Current Status
OK for CofC on 3/27/2025

Permit Application Status History

Submitted 3/21/2024 APPLICANT
Assigned to Plan Check Engineer 3/28/2024 JESSE VIDUYA
Corrections Issued 4/2/2024 JESSE VIDUYA
Quality Review Completed 4/9/2024 HANS SANTIAGO
Building Plans Picked Up 4/15/2024 APPLICANT
Plan Check Approved 5/29/2024 JESSE VIDUYA
Issued 11/21/2024 APPLICANT
OK for CofC 3/27/2025 RICARDO ROBLES

Permit Application Clearance Information

Tenant Habitability Plan Cleared 11/7/2024 KORNEL LELEA

Contact Information

Contractor Alpha Structural Inc; Lic. No.: 663409-B 8334 FOOTHILL BLVD      SUNLAND, CA 91040
Engineer Aparicio,, Daniel Gonzalo; Lic. No.: C92121 19332 AVENIDA DEL SOL      WALNUT, CA 91789

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 12/4/2024 Partial Approval RICARDO ROBLES
Wood Frame 12/4/2024 Not Ready for Inspection RICARDO ROBLES
Deputy Reinf. Concrete 12/5/2024 Conditional Approval RICARDO ROBLES
Deputy Steel/Welding 12/5/2024 Conditional Approval RICARDO ROBLES
Footing/Foundation/Slab 12/5/2024 Approved RICARDO ROBLES
Wood Frame 12/6/2024 Approved RICARDO ROBLES
Interior/Exterior Lathing 1/22/2025 Approved GRANT WOODS
Final 3/17/2025 Partial Approval RICARDO ROBLES
SGSOV-Seismic Gas S/O Valve 3/17/2025 SGSOV Approved RICARDO ROBLES
Smoke Detectors 3/17/2025 Approved RICARDO ROBLES
Final 3/27/2025 OK for CofC RICARDO ROBLES