11844 S ORCHARD AVE 90044

Certificate Information: 11844 S ORCHARD AVE 90044

Application / Permit
24016-10000-09070
Plan Check / Job No.
B24LA04887
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
CONVERT (E) DETACHED GARAGE INTO (N) ACCESSORY DWELLING UNIT PER GCS 65852.2(e)(1)(A)
Permit Issued
Issued on 6/3/2024
Issuing Office
Current Status
CofO Issued on 8/22/2025
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 3/27/2024 APPLICANT
Assigned to Plan Check Engineer 4/1/2024 ISIS ARGUETA
Corrections Issued 4/2/2024 ISIS ARGUETA
Plan Check Approved 5/21/2024 ALEC MOUSAKHANIAN
Issued 6/3/2024 APPLICANT
CofO in Progress 8/21/2025 BEN MOLSTAD
Permit Finaled 8/22/2025 ANSON MAGLASANG
CofO Issued 8/22/2025 ANSON MAGLASANG
Permit Finaled 8/22/2025 ANSON MAGLASANG

Permit Application Clearance Information

Address approval Cleared 5/1/2024 AMBER CAMPBELL
Sewer availability Cleared 5/1/2024 AMBER CAMPBELL
Eng Process Fee Ord 176,300 Cleared 5/16/2024 AMBER CAMPBELL

Contact Information

Contractor Owner-Builder       ,
Engineer Truong,, Phong; Lic. No.: C70784 20439 E CRESTLINE DRIVE      WALNUT, CA 91789

Inspector Information

BEN MOLSTAD, (310) 732-4557 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 8/5/2024 Corrections Issued JOSEPH MCGARRY
Footing/Foundation/Slab 9/10/2024 Corrections Issued BEN MOLSTAD
Footing/Foundation/Slab 9/20/2024 Approved BEN MOLSTAD
PLUMBING-Rough 9/24/2024 Partial Approval BEN MOLSTAD
PLUMBING-Rough 11/8/2024 Not Ready for Inspection BEN MOLSTAD
PLUMBING-Rough 11/12/2024 Partial Approval BEN MOLSTAD
BUILDING-Rough-Frame 11/27/2024 Not Ready for Inspection BEN MOLSTAD
Floor/Roof Diaphrgm/Shear Wall 11/27/2024 Corrections Issued BEN MOLSTAD
Green Building Rough 11/27/2024 Not Ready for Inspection BEN MOLSTAD
METHANE-Rough 11/27/2024 Approved BEN MOLSTAD
BUILDING-Rough-Frame 12/4/2024 Not Ready for Inspection BEN MOLSTAD
Floor/Roof Diaphrgm/Shear Wall 12/4/2024 Partial Approval BEN MOLSTAD
Green Building Rough 12/4/2024 Not Ready for Inspection BEN MOLSTAD
BUILDING-Rough-Frame 12/19/2024 Not Ready for Inspection BEN MOLSTAD
Floor/Roof Diaphrgm/Shear Wall 12/19/2024 Approved BEN MOLSTAD
Green Building Rough 12/19/2024 Not Ready for Inspection BEN MOLSTAD
Wood Frame 12/19/2024 Not Ready for Inspection BEN MOLSTAD
ELECTRICAL-Rough 12/26/2024 Corrections Issued ANTHONY EGSON
Interior/Exterior Lathing 12/26/2024 Corrections Issued ANTHONY EGSON
PLUMBING-Rough 12/26/2024 Corrections Issued ANTHONY EGSON
ELECTRICAL-Rough 2/12/2025 Corrections Issued BEN MOLSTAD
PLUMBING-Rough 2/12/2025 Corrections Issued BEN MOLSTAD
ELECTRICAL-Rough 2/18/2025 Approved BEN MOLSTAD
PLUMBING-Rough 2/18/2025 Approved BEN MOLSTAD
Insulation 3/12/2025 Corrections Issued BEN MOLSTAD
Insulation 3/26/2025 Approved BEN MOLSTAD
Drywall Nailing 4/4/2025 Approved BEN MOLSTAD
Interior/Exterior Lathing 5/2/2025 Approved BEN MOLSTAD
BUILDING-Rough-Frame 6/27/2025 Approved BEN MOLSTAD
ELECTRICAL-Final 6/27/2025 Corrections Issued BEN MOLSTAD
Final 6/27/2025 Corrections Issued BEN MOLSTAD
Green Building Final 6/27/2025 Not Ready for Inspection BEN MOLSTAD
Green Building Rough 6/27/2025 Approved BEN MOLSTAD
HVAC-Final 6/27/2025 Corrections Issued BEN MOLSTAD
SGSOV-Seismic Gas S/O Valve 6/27/2025 SGSOV Not Ready BEN MOLSTAD
Smoke Detectors 6/27/2025 Not Ready for Inspection BEN MOLSTAD
ELECTRICAL-Final 7/16/2025 Corrections Issued BEN MOLSTAD
Final 7/16/2025 Corrections Issued BEN MOLSTAD
Green Building Final 7/16/2025 Not Ready for Inspection BEN MOLSTAD
SGSOV-Seismic Gas S/O Valve 7/16/2025 SGSOV Approved BEN MOLSTAD
Smoke Detectors 7/16/2025 Not Ready for Inspection BEN MOLSTAD
ELECTRICAL-Final 8/21/2025 Approved BEN MOLSTAD
Final 8/21/2025 OK to Issue CofO BEN MOLSTAD
Green Building Final 8/21/2025 Approved BEN MOLSTAD
HVAC-Final 8/21/2025 Approved BEN MOLSTAD
PLUMBING-Final 8/21/2025 Approved BEN MOLSTAD
Service/Power Release 8/21/2025 Approved BEN MOLSTAD
Smoke Detectors 8/21/2025 Approved BEN MOLSTAD