16433 W GLEDHILL ST 91343
Certificate Information: 16433 W GLEDHILL ST 91343
- Application / Permit
- 24016-10000-04639
- Plan Check / Job No.
- X24LA01841
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- 1 Kitchen/2 bathroom remodel for residential buildings (no structural changes). (10) Window and (9) door change-out (same size & type) for residential buildings. Dual glazing, labeled and certified by National Fenestration Rating Council (NFRC), is required for doors and windows replaced in all residential buildings, three stories or less, per Section 150.2(b) 1B of Title 24. Re-roof with Class A or B material weighing less than 6 pounds per sq. ft. over new solid sheathing __17__Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone (VHFHSZ). For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council (CRRC). Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141(b) 2B.
- Permit Issued
- Issued on 2/12/2024
- Issuing Office
- Current Status
- Permit Finaled on 10/23/2025
Permit Application Status History
| Issued | 2/12/2024 | APPLICANT |
| Permit Finaled | 10/22/2025 | GLEN RAND |
Permit Application Clearance Information
| No Data Available. |
Contact Information
| Contractor | Owner-Builder | , |
Inspector Information
| EDMUND LUM, (213) 252-3962 | Office Hours: 7:00-8:00 AM MON-FRI |
| LUCIANO GAUNA, (213) 252-3962 | Office Hours: 7:00-8:00 AM MON-FRI |
| JAIME RIOS, (213) 252-3962 | Office Hours: 7:00-8:00 AM MON-FRI |
| ANDEY CHAPARRO, (213) 252-3962 | Office Hours: 7:00-8:00 AM MON-FRI |
| RYAN BARNES, (213) 252-3962 | Office Hours: 7:00-8:00 AM MON-FRI |
| PATRICK LIEBREGT, (213) 252-3962 | Office Hours: 7:00-8:00 AM MON-FRI |
| GLEN RAND, (213) 252-3962 | Office Hours: 7:00-8:00 AM MON-FRI |
| SHAWN ESHBACH, (213) 252-3962 | Office Hours: 7:00-8:00 AM MON-FRI |
| GABRIEL HERRERA, (213) 252-3962 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 3/5/2024 | Approved | GLEN RAND |
| Pre-Inspection | 3/22/2024 | Approved | RICHARD SIMONS |
| Insulation | 4/11/2024 | Approved | GLEN RAND |
| Drywall Nailing | 4/19/2024 | Approved | GLEN RAND |
| Final | 7/12/2024 | Conditional Approval | GABRIEL HERRERA |
| SGSOV-Seismic Gas S/O Valve | 7/12/2024 | SGSOV Not Ready | GABRIEL HERRERA |
| Smoke Detectors | 7/12/2024 | Approved | GABRIEL HERRERA |
| Final | 10/22/2025 | Permit Finaled | GLEN RAND |
| SGSOV-Seismic Gas S/O Valve | 10/22/2025 | SGSOV Approved | GLEN RAND |