141 N MABERY ROAD 90402
Certificate Information: 141 N MABERY ROAD 90402
- Application / Permit
- 24014-30000-01235
- Plan Check / Job No.
- B24WL00669
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- 1037 SF 2 STORY ADDITION AND REMODEL TO (E) 2 STORY SFD IN BHO AND COASTAL PER ENGINEERS CALCS AND SOILS REPORT WITH 6 MOMENT FRAMES (SOME 2 STORY) AND BENT MOMENT FRAME, CANILEVERED COLUMNS, GRADE BEAMS
- Permit Issued
- Issued on 10/23/2024
- Issuing Office
- Current Status
- Issued on 10/23/2024
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 4/1/2024 | APPLICANT |
| Assigned to Plan Check Engineer | 4/4/2024 | SERGIO SILVA |
| Corrections Issued | 4/17/2024 | SERGIO SILVA |
| Quality Review Completed | 4/18/2024 | KAVIAN REFAHI |
| Building Plans Picked Up | 4/23/2024 | APPLICANT |
| Applicant returned to address corrections | 6/10/2024 | SERGIO SILVA |
| Applicant returned to address corrections | 7/3/2024 | SERGIO SILVA |
| Applicant returned to address corrections | 7/23/2024 | HOOMAN HAJIZADEH |
| Plan Check Approved | 10/23/2024 | SERGIO SILVA |
| Issued | 10/23/2024 | APPLICANT |
Permit Application Clearance Information
| BHO/Hillside ordinance | Cleared | 5/24/2024 | ANDREA SAINT-ANTONIN |
| BHO/Hillside ordinance | Cleared | 5/24/2024 | ANDREA SAINT-ANTONIN |
| BHO/Hillside ordinance | Cleared | 5/24/2024 | ANDREA SAINT-ANTONIN |
| BHO/Hillside ordinance | Cleared | 5/24/2024 | ANDREA SAINT-ANTONIN |
| BHO/Hillside ordinance | Cleared | 5/24/2024 | ANDREA SAINT-ANTONIN |
| Permit | Cleared | 5/24/2024 | ANDREA SAINT-ANTONIN |
| Eng Process Fee Ord 176,300 | Cleared | 5/29/2024 | ANDREA SAINT-ANTONIN |
| Sewer availability | Cleared | 5/29/2024 | ANDREA SAINT-ANTONIN |
| Miscellaneous | Cleared | 6/10/2024 | SERGIO SILVA |
| Coastal Zone | Cleared | 6/19/2024 | NATHAN ROMINE |
| ZA Case | Cleared | 6/19/2024 | NATHAN ROMINE |
| ZI | Cleared | 6/19/2024 | NATHAN ROMINE |
| Trees in Parkway | Cleared | 6/26/2024 | ADALBERTO VERA |
| GPI Written Notices | Cleared | 7/3/2024 | SERGIO SILVA |
| Grading Pre-Inspection | Cleared | 7/3/2024 | SERGIO SILVA |
| Low Impact Development (LID) | Cleared | 7/3/2024 | ERNEST TSE |
| Miscellaneous | Cleared | 7/3/2024 | SERGIO SILVA |
| Roof/Waste drainage to street | Cleared | 7/7/2024 | LIAM ODONOVAN |
| Distance to fire station | Cleared | 7/12/2024 | GILBERT URREA |
| Excavation more than 5-ft deep | Cleared | 10/23/2024 | CALOSHA APPROVED |
| Grading Pre-Inspection | Cleared | 10/23/2024 | ALEXANDER HELFER |
| Miscellaneous | Cleared | 10/23/2024 | SERGIO SILVA |
Contact Information
| Architect | Schabel,, Craig Wesley; Lic. No.: C40563 | 2321 ZENO PLACE VENICE, CA 90291 |
| Contractor | Dowbuilt Inc; Lic. No.: 948772-B | 4001 AURORA AVENUE NORTH SEATTLE, WA 98103 |
| Engineer | Entezam,, Benjamin; Lic. No.: M27247 | 20341 IRVINE AVE STE D3 NEWPORT BEACH, CA 92660 |
| Engineer | Howe,, Carl William; Lic. No.: C44773 | 4358 SEPULVEDA BLVD CULVER CITY, CA 90230 |
| Engineer | Schmahl,, Lawrence Joseph; Lic. No.: L5748 | 11209 HOWARD STREET WHITTIER, CA 90606 |
Inspector Information
| HERBERT GIRON, (310) 914-3891 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation/Setback/Form/Re-Bar | 2/3/2025 | Not Ready for Inspection | JESUS RODRIGUEZ |
| Excavation/Setback/Form/Re-Bar | 3/4/2025 | Partial Inspection | JESUS RODRIGUEZ |
| Footing/Foundation/Slab | 3/27/2025 | Partial Approval | HERBERT GIRON |
| Deputy Drilled-In Anchors | 4/16/2025 | Conditional Approval | HERBERT GIRON |
| Deputy Reinf. Concrete | 4/22/2025 | Conditional Approval | HERBERT GIRON |
| Deputy Steel/Welding | 4/22/2025 | Conditional Approval | TEMISTOCLES CAAL |
| Footing/Foundation/Slab | 4/24/2025 | Partial Approval | HERBERT GIRON |
| Deputy Reinf. Concrete | 4/25/2025 | Conditional Approval | HERBERT GIRON |
| Deputy Drilled-In Anchors | 5/8/2025 | Partial Approval | HERBERT GIRON |
| Excavation/Setback/Form/Re-Bar | 5/8/2025 | Corrections Issued | HERBERT GIRON |
| Footing/Foundation/Slab | 5/8/2025 | Partial Approval | HERBERT GIRON |
| Structural Steel Frame | 5/21/2025 | Partial Approval | STEPHANIE SWANSON |
| Footing/Foundation/Slab | 5/28/2025 | Partial Approval | HERBERT GIRON |
| Deputy Steel/Welding | 6/23/2025 | No Access for Inspection | KENNETH NAGLE |
| Floor/Roof Diaphrgm/Shear Wall | 6/26/2025 | Partial Approval | STEPHANIE SWANSON |
| Structural Steel Frame | 6/26/2025 | Partial Approval | STEPHANIE SWANSON |
| Floor/Roof Diaphrgm/Shear Wall | 7/2/2025 | Partial Approval | HERBERT GIRON |
| Deputy Reinf. Concrete | 7/7/2025 | Conditional Approval | HERBERT GIRON |
| Excavation/Setback/Form/Re-Bar | 7/8/2025 | Approved | HERBERT GIRON |
| Footing/Foundation/Slab | 7/8/2025 | Approved | HERBERT GIRON |
| Deputy Reinf. Concrete | 7/10/2025 | Conditional Approval | HERBERT GIRON |
| Deputy Steel/Welding | 7/29/2025 | Conditional Approval | HERBERT GIRON |
| Deputy Wood Construction | 8/6/2025 | Conditional Approval | HERBERT GIRON |
| Floor/Roof Diaphrgm/Shear Wall | 8/7/2025 | Corrections Issued | HERBERT GIRON |
| HVAC-Rough | 8/25/2025 | Partial Inspection | STEPHANIE SWANSON |
| Deputy Drilled-In Anchors | 8/26/2025 | Conditional Approval | HERBERT GIRON |
| Deputy Wood Construction | 9/22/2025 | Conditional Approval | HERBERT GIRON |
| Floor/Roof Diaphrgm/Shear Wall | 9/23/2025 | Approved | MEL KHACHATOURIAN |
| PLUMBING-Rough | 11/21/2025 | Corrections Issued | HERBERT GIRON |
| HVAC-Rough | 12/10/2025 | Corrections Issued | HERBERT GIRON |
| ELECTRICAL-Rough | 12/19/2025 | Corrections Issued | HERBERT GIRON |
| PLUMBING-Rough | 12/19/2025 | Approved | HERBERT GIRON |
| ELECTRICAL-Rough | 12/24/2025 | Approved | BOBBY KEY |
| Interior/Exterior Lathing | 1/7/2026 | Partial Approval | TEMISTOCLES CAAL |
| Pre-Inspection | 1/12/2026 | Partial Inspection | HERBERT GIRON |
| Interior/Exterior Lathing | 1/22/2026 | Partial Approval | HERBERT GIRON |
| BUILDING-Rough-Frame | 2/9/2026 | Partial Approval | HERBERT GIRON |
| Green Building Rough | 2/9/2026 | Approved | HERBERT GIRON |
| HVAC-Rough | 2/9/2026 | Approved | HERBERT GIRON |
| Interior/Exterior Lathing | 2/9/2026 | Partial Approval | HERBERT GIRON |
| Special/Order Compliance | 2/9/2026 | Corrections Issued | HERBERT GIRON |
| Insulation | 2/13/2026 | Not Ready for Inspection | HERBERT GIRON |
| Insulation | 2/18/2026 | Conditional Approval | KENNETH NAGLE |
| BUILDING-Rough-Frame | 3/5/2026 | Approved | HERBERT GIRON |
| Drywall Nailing | 3/5/2026 | Approved | HERBERT GIRON |
| Insulation | 3/5/2026 | Approved | HERBERT GIRON |
| Special/Order Compliance | 3/5/2026 | Partial Inspection | JUAN VALENZUELA |
| Shower Pan | 3/19/2026 | Approved | HERBERT GIRON |
| Special/Order Compliance | 3/19/2026 | Approved | JUAN VALENZUELA |
| Interior/Exterior Lathing | 4/1/2026 | Partial Approval | HERBERT GIRON |
| Interior/Exterior Lathing | 4/16/2026 | Partial Approval | HERBERT GIRON |