11723 W ADDISON ST 91607
Certificate Information: 11723 W ADDISON ST 91607
- Application / Permit
- 24014-20000-04968
- Plan Check / Job No.
- B24VN22281
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- ADD 41'1" X 17' IRREGULAR SHAPED 1ST AND 2ND STORY TO & CONVERT (E) 19'1" X 17'2" DETACHED TWO CAR GARAGE TO ACCESSORY DWELLING UNIT PER LAMC 12.22 A.33 (c) and (e) , ALL WORK PER ENGINEERING
- Permit Issued
- Issued on 3/7/2025
- Issuing Office
- Valley
- Current Status
- CofO in Progress on 5/19/2026
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 11/6/2024 | APPLICANT |
| Assigned to Plan Check Engineer | 11/21/2024 | RARES BODEA |
| Corrections Issued | 12/3/2024 | RARES BODEA |
| Quality Review Completed | 12/3/2024 | STEVEN KIM |
| Building Plans Picked Up | 12/5/2024 | APPLICANT |
| Plan Check Approved | 3/7/2025 | RARES BODEA |
| Issued | 3/7/2025 | APPLICANT |
| CofO in Progress | 5/19/2026 | JAVIER RAMOS JR |
Permit Application Clearance Information
| Construction near power lines | Cleared | 12/2/2024 | ENRIQUE ACOSTA |
| Address approval | Cleared | 12/12/2024 | BIAINA HARITUNIAN |
| Eng Process Fee Ord 176,300 | Cleared | 12/12/2024 | BIAINA HARITUNIAN |
| Roof/Waste drainage to street | Cleared | 12/12/2024 | BIAINA HARITUNIAN |
| Sewer availability | Cleared | 12/12/2024 | BIAINA HARITUNIAN |
| Miscellaneous | Cleared | 12/19/2024 | JOANNA MARROQUIN |
| Specific Plan | Cleared | 12/19/2024 | JOANNA MARROQUIN |
| ZI | Cleared | 12/19/2024 | JOANNA MARROQUIN |
| ZI | Cleared | 12/19/2024 | JOANNA MARROQUIN |
Contact Information
| Contractor | D K R Construction Inc; Lic. No.: 1070450-B | 7110 FOREST HILLS RD WEST HILLS, CA 91307 |
| Engineer | Kaballo,, Amir; Lic. No.: C90707 | 20984 UPTOWN AVE #112 BOCA RATON, FL 33428 |
Inspector Information
| JAVIER RAMOS JR, (818) 374-1163 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| PLUMBING-Rough | 5/13/2025 | Partial Approval | JAVIER RAMOS JR |
| Deputy Drilled-In Anchors | 5/21/2025 | Conditional Approval | JUAN VALENZUELA |
| Footing/Foundation/Slab | 5/21/2025 | Corrections Issued | JAVIER RAMOS JR |
| Deputy Wood Construction | 6/5/2025 | Conditional Approval | JUAN VALENZUELA |
| Floor/Roof Diaphrgm/Shear Wall | 6/5/2025 | Corrections Issued | JAVIER RAMOS JR |
| Footing/Foundation/Slab | 6/5/2025 | Approved | JAVIER RAMOS JR |
| Floor/Roof Diaphrgm/Shear Wall | 7/29/2025 | Corrections Issued | ROBERTO PALACIOS-LOPEZ |
| PLUMBING-Rough | 7/29/2025 | Corrections Issued | ROBERTO PALACIOS-LOPEZ |
| BUILDING-Rough-Frame | 7/31/2025 | Corrections Issued | JAVIER RAMOS JR |
| Floor/Roof Diaphrgm/Shear Wall | 7/31/2025 | Corrections Issued | JAVIER RAMOS JR |
| PLUMBING-Rough | 7/31/2025 | Approved | JAVIER RAMOS JR |
| ELECTRICAL-Rough | 8/25/2025 | Approved | JAVIER RAMOS JR |
| Floor/Roof Diaphrgm/Shear Wall | 8/25/2025 | Not Ready for Inspection | JAVIER RAMOS JR |
| HVAC-Rough | 8/25/2025 | Partial Approval | JAVIER RAMOS JR |
| Sewer | 9/5/2025 | Approved | JAVIER RAMOS JR |
| Shower Pan | 9/5/2025 | Approved | JAVIER RAMOS JR |
| Underground Mechanical | 9/5/2025 | Approved | JAVIER RAMOS JR |
| Interior/Exterior Lathing | 9/9/2025 | Corrections Issued | JAVIER RAMOS JR |
| BUILDING-Rough-Frame | 9/11/2025 | Corrections Issued | JAVIER RAMOS JR |
| Floor/Roof Diaphrgm/Shear Wall | 9/11/2025 | Approved | JAVIER RAMOS JR |
| Interior/Exterior Lathing | 9/11/2025 | Approved | JAVIER RAMOS JR |
| BUILDING-Rough-Frame | 9/19/2025 | Approved | JAVIER RAMOS JR |
| Green Building Rough | 9/19/2025 | Approved | JAVIER RAMOS JR |
| Insulation | 9/19/2025 | Approved | JAVIER RAMOS JR |
| Drywall Nailing | 9/25/2025 | Approved | JAVIER RAMOS JR |
| ELECTRICAL-Final | 2/12/2026 | Approved | JAVIER RAMOS JR |
| Final | 2/12/2026 | Corrections Issued | JAVIER RAMOS JR |
| HVAC-Final | 2/12/2026 | Approved | JAVIER RAMOS JR |
| PLUMBING-Final | 2/12/2026 | Approved | JAVIER RAMOS JR |
| SGSOV-Seismic Gas S/O Valve | 2/12/2026 | SGSOV Not Required | JAVIER RAMOS JR |
| Service/Power Release | 2/12/2026 | Approved | JAVIER RAMOS JR |
| Smoke Detectors | 2/12/2026 | Approved | JAVIER RAMOS JR |
| Final | 5/18/2026 | OK to Issue CofO | JAVIER RAMOS JR |
| Green Building Final | 5/18/2026 | Approved | JAVIER RAMOS JR |