8407 N JUMILLA AVE 91306

Certificate Information: 8407 N JUMILLA AVE 91306

Application / Permit
24014-20000-04546
Plan Check / Job No.
B24VN19420
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
NEW 30'7" X 35'5-1/4" IRREGULARLY SHAPED ADDITION TO REAR OF EXISTING SINGLE FAMILY DWELLING. REMODEL SFD AS WELL. ENCLOSE EXISTING FRONT PORCH TO BECOME PART OF SFD. NFPA-13D FIRE SPRINKLERS TO BE INSTALLED THROUGHOUT. ALL WORK DONE PER ENGINEER DESIGN.
Permit Issued
Issued on 5/1/2025
Issuing Office
Current Status
CofO Issued on 4/4/2026
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 10/10/2024 APPLICANT
Assigned to Plan Check Engineer 10/16/2024 MADISON ODELL
Corrections Issued 10/16/2024 MADISON ODELL
Applicant returned to address corrections 2/28/2025 MADISON ODELL
Applicant returned to address corrections 4/3/2025 MADISON ODELL
Plan Check Approved 4/23/2025 MADISON O'DELL
Issued 5/1/2025 APPLICANT
CofO in Progress 12/17/2025 CHRIS CHRISTENSEN
Permit Finaled 4/4/2026 MICHAEL PELHAM
CofO Issued 4/4/2026 MICHAEL PELHAM
Permit Finaled 4/4/2026 MICHAEL PELHAM

Permit Application Clearance Information

Eng Process Fee Ord 176,300 Cleared 10/20/2024 LEE GUILBEAUX
Roof/Waste drainage to street Cleared 10/20/2024 LEE GUILBEAUX
Sewer availability Cleared 10/20/2024 LEE GUILBEAUX
Public Works-Highway Ded. Cleared 10/20/2024 LEE GUILBEAUX
ZA Case Cleared 1/7/2025 DORIAN AGUILAR

Contact Information

Contractor Owner-Builder       ,
Engineer Zelada,, Mynor Anibal; Lic. No.: C48666 22634 SYLVAN ST      WOODLAND HILLS, CA 91367

Inspector Information

JEFFREY HARTLINE, (818) 774-4320 Office Hours: 7:00-8:00 AM MON-FRI
CHRIS CHRISTENSEN, (818) 774-4320 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Deputy Drilled-In Anchors 6/24/2025 Conditional Approval CHRIS CHRISTENSEN
Footing/Foundation/Slab 6/30/2025 Approved CHRIS CHRISTENSEN
Floor/Roof Diaphrgm/Shear Wall 7/8/2025 Partial Approval CHRIS CHRISTENSEN
PLUMBING-Rough 7/8/2025 Partial Approval CHRIS CHRISTENSEN
Floor/Roof Diaphrgm/Shear Wall 7/11/2025 Partial Approval CHRIS CHRISTENSEN
Floor/Roof Diaphrgm/Shear Wall 7/30/2025 Approved CHRIS CHRISTENSEN
ELECTRICAL-Rough 8/12/2025 Approved JEFFREY HARTLINE
HVAC-Rough 8/12/2025 Approved JEFFREY HARTLINE
Interior/Exterior Lathing 8/12/2025 Partial Approval JEFFREY HARTLINE
PLUMBING-Rough 8/12/2025 Approved JEFFREY HARTLINE
BUILDING-Rough-Frame 8/14/2025 Approved JEFFREY HARTLINE
Green Building Rough 8/14/2025 Approved JEFFREY HARTLINE
Verify Sprinkler Sign Off 8/14/2025 Approved JEFFREY HARTLINE
Insulation 8/18/2025 Approved CHRIS CHRISTENSEN
Interior/Exterior Lathing 8/18/2025 Approved CHRIS CHRISTENSEN
Drywall Nailing 8/21/2025 Approved CHRIS CHRISTENSEN
Interior/Exterior Lathing 8/21/2025 Partial Approval CHRIS CHRISTENSEN
ELECTRICAL-Final 11/25/2025 Approved CHRIS CHRISTENSEN
Final 11/25/2025 Corrections Issued CHRIS CHRISTENSEN
Green Building Final 11/25/2025 Approved CHRIS CHRISTENSEN
HVAC-Final 11/25/2025 Approved CHRIS CHRISTENSEN
PLUMBING-Final 11/25/2025 Approved CHRIS CHRISTENSEN
SGSOV-Seismic Gas S/O Valve 11/25/2025 SGSOV Approved CHRIS CHRISTENSEN
Smoke Detectors 11/25/2025 Approved CHRIS CHRISTENSEN
Final 12/16/2025 OK to Issue CofO CHRIS CHRISTENSEN