1541 N OGDEN DR 90046
Certificate Information: 1541 N OGDEN DR 90046
- Application / Permit
- 24014-20000-02935
- Plan Check / Job No.
- B24VN09516
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- INTERIOR/EXTERIOR REMODEL OF EXISTING SINGLE FAMILY DWELLING AND RE-ROOFING. ADDITION (14'-8 5/8" X 2'-10") TO FIRST STORY AND ADDITION (21'-11" X 18'-1") TO SECOND STORY.
- Permit Issued
- Issued on 10/8/2024
- Issuing Office
- Current Status
- Issued on 10/8/2024
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 7/5/2024 | APPLICANT |
| Assigned to Plan Check Engineer | 8/1/2024 | VAHAN JIVALAGIAN |
| Corrections Issued | 8/8/2024 | VAHAN JIVALAGIAN |
| Quality Review Completed | 8/8/2024 | OMID HEDAYAT |
| Building Plans Picked Up | 8/9/2024 | APPLICANT |
| Applicant returned to address corrections | 9/11/2024 | VAHAN JIVALAGIAN |
| Applicant returned to address corrections | 9/27/2024 | VAHAN JIVALAGIAN |
| Plan Check Approved | 10/3/2024 | VAHAN JIVALAGIAN |
| Issued | 10/8/2024 | APPLICANT |
Permit Application Clearance Information
| Roof/Waste drainage to street | Cleared | 8/21/2024 | TREVOR QUAN |
| Sewer availability | Cleared | 8/21/2024 | TREVOR QUAN |
| Eng Process Fee Ord 176,300 | Cleared | 8/23/2024 | TREVOR QUAN |
| HPOZ | Cleared | 9/25/2024 | JORGE RUIZ |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Judd,, Shane Dennis; Lic. No.: C70991 | 17 E HIGH ST STE A MOORPARK, CA 93021 |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 11/19/2024 | Corrections Issued | BRIAN SULLIVAN |
| Pre-Inspection | 11/19/2024 | Partial Inspection | BRIAN SULLIVAN |
| Footing/Foundation/Slab | 11/25/2024 | Approved | BRIAN SULLIVAN |
| BUILDING-Rough-Frame | 4/23/2026 | Approved | ROY SPAULDING |
| Drywall Nailing | 4/23/2026 | Approved | ROY SPAULDING |
| FLOOD-Proofing Certificate | 4/23/2026 | Approved | ROY SPAULDING |
| Final | 4/23/2026 | Not Ready for Inspection | ROY SPAULDING |
| Green Building Final | 4/23/2026 | Approved | ROY SPAULDING |
| Green Building Rough | 4/23/2026 | Approved | ROY SPAULDING |
| SGSOV-Seismic Gas S/O Valve | 4/23/2026 | SGSOV Approved | ROY SPAULDING |
| Smoke Detectors | 4/23/2026 | Approved | ROY SPAULDING |
| Final | 5/20/2026 | Corrections Issued | ROY SPAULDING |
| Final | 5/21/2026 | Not Ready for Inspection | ROY SPAULDING |