6514-6518 N ROYER AVE 91307
Certificate Information: 6514-6518 N ROYER AVE 91307
- Application / Permit
- 24014-20000-02292
- Plan Check / Job No.
- B24VN07487
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- CONVERT EXISTING ATTACHED 2-CAR GARAGE INTO JADU (401 SQFT) W/2ND STORY ADDITION OF AN ADU (402 SQFT) W/1ST FLOOR ADDITION (656 SQFT) TO THE EXISTING SINGLE FAMILY DWELLING. W/NFPA 13D SPRINKLERS THROUGHOUT
- Permit Issued
- Issued on 5/19/2025
- Issuing Office
- Current Status
- CofO in Progress on 5/21/2026
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 6/4/2024 | APPLICANT |
| Assigned to Plan Check Engineer | 6/20/2024 | PETER MOSESIAN |
| Corrections Issued | 6/25/2024 | PETER MOSESIAN |
| Quality Review Completed | 7/5/2024 | OMID HEDAYAT |
| Applicant returned to address corrections | 9/4/2024 | PETER MOSESIAN |
| Plan Check Approved | 9/30/2024 | PETER MOSESIAN |
| Issued | 5/19/2025 | APPLICANT |
| CofO in Progress | 5/21/2026 | TROY SANDERS |
Permit Application Clearance Information
| Miscellaneous | Cleared | 7/5/2024 | BRENNEN OBETO |
| Address approval | Cleared | 7/6/2024 | CARLOS AGUILERA |
| Roof/Waste drainage to street | Cleared | 7/6/2024 | CARLOS AGUILERA |
| Eng Process Fee Ord 176,300 | Cleared | 7/10/2024 | CARLOS AGUILERA |
| Sewer availability | Cleared | 7/10/2024 | CARLOS AGUILERA |
Contact Information
| Contractor | Atm Remodeling & Development Inc; Lic. No.: 1119937-B | , |
| Engineer | Fernandez,, Samuel; Lic. No.: C70886 | 8225 BRIMFIELD AVE PANORAMA CITY, CA 91402 |
Inspector Information
| GEVORK IPCHYAN, (818) 774-4308 | Office Hours: 7:00-8:00 AM MON-FRI |
| TROY SANDERS, (818) 774-4308 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 7/9/2025 | Partial Inspection | TROY SANDERS |
| Deputy Reinf. Concrete | 7/14/2025 | Conditional Approval | HENRY KIM |
| Floor/Roof Diaphrgm/Shear Wall | 7/30/2025 | Partial Approval | TROY SANDERS |
| Insulation | 7/30/2025 | Partial Approval | TROY SANDERS |
| PLUMBING-Rough | 7/30/2025 | Partial Approval | TROY SANDERS |
| Footing/Foundation/Slab | 8/14/2025 | Approved | TROY SANDERS |
| Insulation | 8/14/2025 | Not Ready for Inspection | TROY SANDERS |
| PLUMBING-Rough | 8/14/2025 | Partial Approval | TROY SANDERS |
| Deputy Reinf. Concrete | 8/18/2025 | Conditional Approval | HENRY KIM |
| Floor/Roof Diaphrgm/Shear Wall | 9/24/2025 | Corrections Issued | JON MCHUGH |
| BUILDING-Rough-Frame | 10/7/2025 | No Access for Inspection | TROY SANDERS |
| Floor/Roof Diaphrgm/Shear Wall | 10/7/2025 | Not Ready for Inspection | TROY SANDERS |
| Rough-Elec/Plmb/HVAC | 10/7/2025 | Not Ready for Inspection | TROY SANDERS |
| Shower Pan | 10/7/2025 | Not Ready for Inspection | TROY SANDERS |
| BUILDING-Rough-Frame | 10/9/2025 | Partial Approval | TROY SANDERS |
| Floor/Roof Diaphrgm/Shear Wall | 10/9/2025 | Partial Approval | TROY SANDERS |
| Rough-Elec/Plmb/HVAC | 10/9/2025 | Approved | TROY SANDERS |
| Shower Pan | 10/9/2025 | Approved | TROY SANDERS |
| Floor/Roof Diaphrgm/Shear Wall | 10/23/2025 | Not Ready for Inspection | TROY SANDERS |
| Insulation | 10/23/2025 | Approved | TROY SANDERS |
| Interior/Exterior Lathing | 10/23/2025 | Partial Approval | TROY SANDERS |
| Drywall Nailing | 10/28/2025 | Approved | TROY SANDERS |
| BUILDING-Rough-Frame | 5/7/2026 | Approved | TROY SANDERS |
| ELECTRICAL-Final | 5/7/2026 | Approved | TROY SANDERS |
| Final | 5/7/2026 | Corrections Issued | TROY SANDERS |
| HVAC-Final | 5/7/2026 | Approved | TROY SANDERS |
| PLUMBING-Final | 5/7/2026 | Approved | TROY SANDERS |
| SGSOV-Seismic Gas S/O Valve | 5/7/2026 | SGSOV Approved | TROY SANDERS |
| Smoke Detectors | 5/7/2026 | Approved | TROY SANDERS |
| Final | 5/20/2026 | OK to Issue CofO | TROY SANDERS |